IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

231

matching recommendations
Reset
NAICS 332 Fabricated Metal Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0077 # 03 Y:2012 03 2012 COVER OPEN TANKS $4,562 $154 Not Implemented
UA0077 # 04 Y:2012 04 2012 USE OPTIMUM THICKNESS INSULATION $880 $913 Not Implemented
UA0077 # 05 Y:2012 05 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $24,553 $800 Not Implemented
UA0077 # 06 Y:2012 06 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,608 $2,000 Not Implemented
UA0077 # 07 Y:2012 07 2012 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,398 $58 Not Implemented
UA0072 # 01 Y:2012 01 2012 RECOVER WASTE HEAT FROM EQUIPMENT $17,176 $2,039 Implemented
UA0072 # 02 Y:2012 02 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,742 $3,900 Implemented
UA0072 # 03 Y:2012 03 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $14,647 $80 Implemented
UA0072 # 04 Y:2012 04 2012 INSTALL OCCUPANCY SENSORS $6,856 $7,937 Not Implemented
UA0072 # 05 Y:2012 05 2012 USE PHOTOCELL CONTROLS $1,851 $1,030 Not Implemented
UA0072 # 06 Y:2012 06 2012 PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT $3,939 $9,445 Not Implemented
UA0072 # 07 Y:2012 07 2012 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $2,750 $415 Not Implemented
UA3011 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,307 $26,402 Not Implemented
UA3011 # 02 Y:2011 02 2011 USE PHOTOCELL CONTROLS $575 $225 Implemented
UA3011 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $23,842 $5,000 Implemented
UA3011 # 04 Y:2011 04 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,087 $640 Not Implemented
UA3011 # 05 Y:2011 05 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $8,304 $1,800 Not Implemented
UA3011 # 06 Y:2011 06 2011 REPAIR AND ELIMINATE STEAM LEAKS $515 $1,030 Implemented
UA3011 # 07 Y:2011 07 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $7,440 $4,586 Not Implemented
UA3011 # 08 Y:2011 08 2011 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,373 $320 Not Implemented
UA3011 # 09 Y:2011 09 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,493 $70,000 Not Implemented
UA3011 # 10 Y:2011 10 2011 USE RADIANT HEATER FOR SPOT HEATING $13,650 $9,480 Not Implemented
UA3011 # 11 Y:2011 11 2011 INSTALL TIMERS AND/OR THERMOSTATS $366 $510 Implemented
UA3011 # 12 Y:2011 12 2011 INSTALL TIMERS AND/OR THERMOSTATS $843 $50 Implemented
UA3011 # 13 Y:2011 13 2011 INSULATE BARE EQUIPMENT $5,251 $1,503 Not Implemented