IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

160

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0019 # 11 Y:2008 11 2008 PREHEAT COMBUSTION AIR WITH WASTE HEAT $48,714 $9,100 Not Implemented
UA0002 # 01 Y:2007 01 2007 INSULATE BARE EQUIPMENT $20,117 $824 Not Implemented
UA0002 # 02 Y:2007 02 2007 INSULATE BARE EQUIPMENT $34,488 $1,462 Not Implemented
UA0002 # 03 Y:2007 03 2007 REPAIR AND ELIMINATE STEAM LEAKS $35,628 $600 Implemented
UA0002 # 04 Y:2007 04 2007 METER WASTE WATER $6,725 $0 Not Implemented
UA0002 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,648 $15,057 Not Implemented
UA0002 # 06 Y:2007 06 2007 INSTALL / REPAIR INSULATION ON STEAM LINES $11,078 $3,916 Implemented
MS0229 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,960 $16,317 n/a
MS0229 # 02 Y:2003 02 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,125 $3,106 Not Implemented
MS0229 # 03 Y:2003 03 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,323 $7,734 Not Implemented
MS0229 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $987 $196 Not Implemented
MS0229 # 05 Y:2003 05 2003 REPAIR AND ELIMINATE STEAM LEAKS $967 $67 Not Implemented
MS0229 # 06 Y:2003 06 2003 INSTALL TIMERS AND/OR THERMOSTATS $434 $472 Not Implemented
MS0229 # 07 Y:2003 07 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $61 $140 Not Implemented
MS0109 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,140 $3,776 Implemented
MS0109 # 02 Y:1998 02 1998 INSTALL TIMERS AND/OR THERMOSTATS $402 $232 Implemented
MS0109 # 03 Y:1998 03 1998 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,627 $6,800 Not Implemented
MS0109 # 04 Y:1998 04 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,919 $17,023 Not Implemented
MS0109 # 05 Y:1998 05 1998 INSULATE BARE EQUIPMENT $1,077 $1,898 Implemented
MS0109 # 06 Y:1998 06 1998 OPTIMIZE PLANT POWER FACTOR $14,495 $39,000 Not Implemented
MS0109 # 07 Y:1998 07 1998 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,287 $0 Implemented
MS0109 # 08 Y:1998 08 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $5,944 $6,500 Not Implemented
MS0109 # 09 Y:1998 09 1998 BURN WASTE OIL FOR HEAT $8,290 $4,765 Not Implemented
MS0109 # 10 Y:1998 10 1998 $283,220 $1,800,000 Not Implemented
GT0637 # 01 Y:1998 01 1998 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $4,126 $3,000 Not Implemented