Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

87

matching recommendations
Reset
SIC 331 Blast Furnace And Basic Steel Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AR0163 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,383 $120 Not Implemented
AR0163 # 06 Y:1999 06 1999 $3,065 $225 Not Implemented
AR0163 # 05 Y:1999 05 1999 $251,669 $66,400 Not Implemented
AR0163 # 04 Y:1999 04 1999 USE OPTIMUM THICKNESS INSULATION $11,267 $1,408 Not Implemented
AR0163 # 03 Y:1999 03 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $226 $2,400 Not Implemented
AR0146 # 01 Y:1998 01 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,771 $840 Implemented
AR0146 # 02 Y:1998 02 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,850 $300 Implemented
AR0146 # 03 Y:1998 03 1998 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $29,234 $18,900 Implemented
AR0146 # 04 Y:1998 04 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,398 $1,340 Implemented
AR0146 # 05 Y:1998 05 1998 REDUCE OR ELIMINATE WASTE $224,855 $8,100 Implemented
AR0146 # 07 Y:1998 07 1998 $3,780 $0 Implemented
AR0146 # 08 Y:1998 08 1998 $98,162 $386,400 Implemented
AR0146 # 06 Y:1998 06 1998 REPROCESS SPENT OILS ON SITE FOR RE-USE $17,264 $0 Not Implemented
AR0104 # 06 Y:1996 06 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,389 $3,380 Implemented
AR0104 # 05 Y:1996 05 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,273 $3,000 Not Implemented
AR0104 # 07 Y:1996 07 1996 INSULATE BARE EQUIPMENT $307 $100 Implemented
AR0104 # 01 Y:1996 01 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $609 $355 Implemented
AR0104 # 02 Y:1996 02 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $369 $1,000 Implemented
AR0104 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,047 $180 Implemented
AR0104 # 04 Y:1996 04 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,042 $530 Implemented
AR0104 # 08 Y:1996 08 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $296 $0 Implemented
AR0104 # 09 Y:1996 09 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,805 $6,000 Not Implemented
AR0035 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,123 $587 Implemented
AR0035 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $82,541 $94,050 Implemented
AR0035 # 03 Y:1995 03 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $15,785 $3,660 Implemented