Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

55

matching recommendations
Reset
SIC 336 Nonferrous Foundries (castings)
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AR0083 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $830 $300 Not Implemented
AR0083 # 06 Y:1996 06 1996 USE RADIANT HEATER FOR SPOT HEATING $4,647 $1,000 Implemented
AR0083 # 07 Y:1996 07 1996 MAINTAIN MACHINES TO REDUCE LEAKS $4,380 $1,000 Implemented
AR0070 # 07 Y:1995 07 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,086 $1,000 Implemented
AR0070 # 12 Y:1995 12 1995 MODIFY MATERIAL APPLICATION METHODS $300,000 $3,000 Implemented
AR0070 # 11 Y:1995 11 1995 MINIMIZE WATER USAGE $840 $200 Implemented
AR0070 # 10 Y:1995 10 1995 OPTIMIZE PLANT POWER FACTOR $31,084 $33,795 Not Implemented
AR0070 # 09 Y:1995 09 1995 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $100,584 $0 Implemented
AR0070 # 08 Y:1995 08 1995 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $9,267 $0 Implemented
AR0070 # 06 Y:1995 06 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $21,997 $300 Implemented
AR0070 # 05 Y:1995 05 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $13,029 $2,250 Implemented
AR0070 # 04 Y:1995 04 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,027 $0 Implemented
AR0070 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,164 $10,900 Implemented
AR0070 # 02 Y:1995 02 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $9,430 $3,790 Implemented
AR0070 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,147 $1,779 Implemented
LT0137 # 01 Y:1988 01 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,880 $0 Implemented
LT0137 # 08 Y:1988 08 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $38 $37 Not Implemented
LT0137 # 07 Y:1988 07 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,020 $1,855 Not Implemented
LT0137 # 06 Y:1988 06 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $695 $0 Not Implemented
LT0137 # 05 Y:1988 05 1988 INSTALL TIMERS AND/OR THERMOSTATS $1,085 $600 Not Implemented
LT0137 # 04 Y:1988 04 1988 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $17,073 $6,027 Not Implemented
LT0137 # 03 Y:1988 03 1988 INSULATE BARE EQUIPMENT $1,250 $1,785 Not Implemented
LT0137 # 02 Y:1988 02 1988 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $21,475 $20,000 Not Implemented
LT0062 # 05 Y:1986 05 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $20,440 $22,200 Not Implemented
LT0062 # 04 Y:1986 04 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $79,027 $80,080 Not Implemented