Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,437
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0870 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,957 | $0 | Implemented |
OK0870 # 03 Y:2013 | 03 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $1,212 | $2,500 | Not Implemented |
OK0870 # 01 Y:2013 | 01 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $8,384 | $0 | Implemented |
OK0870 # 04 Y:2013 | 04 | 2013 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $20,022 | $105,120 | Not Implemented |
OK0864 # 02 Y:2013 | 02 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $655 | $1,128 | Not Implemented |
OK0864 # 09 Y:2013 | 09 | 2013 | USE FLUE GAS RECUPERATION TO REDUCE VOC | $79,353 | $32,100 | Implemented |
OK0864 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $33,277 | $58,900 | Not Implemented |
OK0864 # 03 Y:2013 | 03 | 2013 | INSULATE BARE EQUIPMENT | $2,872 | $1,478 | Not Implemented |
OK0864 # 05 Y:2013 | 05 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $8,999 | $27,500 | Not Implemented |
OK0864 # 06 Y:2013 | 06 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,158 | $10,250 | Implemented |
OK0864 # 04 Y:2013 | 04 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $5,084 | $0 | Implemented |
OK0864 # 07 Y:2013 | 07 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $46,176 | $10,642 | Implemented |
OK0864 # 08 Y:2013 | 08 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $127,574 | $25,000 | Not Implemented |
OK0863 # 04 Y:2013 | 04 | 2013 | INSULATE BARE EQUIPMENT | $10,721 | $1,250 | Not Implemented |
MZ0129 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $47,580 | $267,500 | Implemented |
MZ0129 # 05 Y:2013 | 05 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20,763 | $63,637 | Implemented |
OK0863 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $3,208 | $4,450 | Not Implemented |
MZ0129 # 01 Y:2013 | 01 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $56,550 | $18,200 | Implemented |
MZ0129 # 11 Y:2013 | 11 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,450 | $0 | Implemented |
MZ0129 # 06 Y:2013 | 06 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $156 | $0 | Not Implemented |
MZ0129 # 09 Y:2013 | 09 | 2013 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $31,162 | $150,000 | Not Implemented |
OK0863 # 01 Y:2013 | 01 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,703 | $2,500 | Not Implemented |
OK0863 # 02 Y:2013 | 02 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,069 | $22,428 | Not Implemented |
MZ0129 # 08 Y:2013 | 08 | 2013 | INSTALL OCCUPANCY SENSORS | $998 | $190 | Implemented |
MZ0129 # 04 Y:2013 | 04 | 2013 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $1,563 | $760 | Implemented |