IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

183

matching recommendations
Reset
NAICS 3115 Dairy Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0360 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,717 $10,269 Implemented
LM0116 # 01 Y:2006 01 2006 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $12,946 $0 Not Implemented
LM0116 # 02 Y:2006 02 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $111,472 $82,700 Implemented
LM0116 # 03 Y:2006 03 2006 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,913 $7,000 Not Implemented
LM0116 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $230,613 $69,350 Implemented
LM0116 # 05 Y:2006 05 2006 $337,500 $5,000 Not Implemented
LM0116 # 06 Y:2006 06 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $260 $0 Implemented
SF0310 # 01 Y:2005 01 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,347 $480 Not Implemented
SF0310 # 02 Y:2005 02 2005 REPAIR AND ELIMINATE STEAM LEAKS $728 $120 Not Implemented
SF0310 # 03 Y:2005 03 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,633 $3,457 Not Implemented
SF0310 # 04 Y:2005 04 2005 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,150 $2,900 Not Implemented
SF0310 # 05 Y:2005 05 2005 INSTALL OCCUPANCY SENSORS $1,456 $1,635 Not Implemented
SF0310 # 06 Y:2005 06 2005 INSULATE BARE EQUIPMENT $1,570 $1,687 Not Implemented
SF0310 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,218 $24,484 Not Implemented
SF0310 # 08 Y:2005 08 2005 UPGRADE CONTROLS ON COMPRESSORS $6,777 $18,995 Not Implemented
SF0310 # 09 Y:2005 09 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,603 $14,240 Not Implemented
SF0310 # 10 Y:2005 10 2005 USE DECANTING, FLOTATION TO REMOVE CONTAMINANTS $38,197 $66,900 Not Implemented
SF0275 # 01 Y:2004 01 2004 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,063 $739 Not Implemented
SF0275 # 02 Y:2004 02 2004 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $49,562 $39,000 Implemented
SF0275 # 03 Y:2004 03 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,238 $0 Implemented
SF0275 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,909 $3,688 Implemented
SF0275 # 05 Y:2004 05 2004 COVER OPEN TANKS $715 $1,469 Not Implemented
SF0275 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,604 $12,835 Not Implemented
SF0275 # 07 Y:2004 07 2004 INSTALL OCCUPANCY SENSORS $1,197 $4,096 Not Implemented
SF0275 # 08 Y:2004 08 2004 USE PHOTOCELL CONTROLS $613 $2,971 Not Implemented