Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

281

matching recommendations
Reset
SIC 24 Lumber And Wood Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0057 # 06 Y:1995 06 1995 OPTIMIZE PLANT POWER FACTOR $3,137 $4,459 Not Implemented
SF0057 # 07 Y:1995 07 1995 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $17,555 $37,000 Not Implemented
SF0057 # 08 Y:1995 08 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $142,905 $479,000 Not Implemented
NV0017 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,998 $0 Implemented
NV0017 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,930 $888 Implemented
NV0017 # 03 Y:1995 03 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,689 $200 Implemented
NV0017 # 04 Y:1995 04 1995 REDUCE GLAZED AREAS IN BUILDINGS $151 $653 Not Implemented
NV0017 # 05 Y:1995 05 1995 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $10,560 $0 Not Implemented
SD0051 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,002 $1,890 Implemented
SD0051 # 02 Y:1993 02 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,549 $3,320 Implemented
SD0051 # 03 Y:1993 03 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $223 $20 Not Implemented
SD0051 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $544 $80 Not Implemented
SD0051 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $102 $0 Implemented
SD0051 # 06 Y:1993 06 1993 INSTALL SET-BACK TIMERS $771 $1,080 Implemented
SD0051 # 07 Y:1993 07 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $1,314 $2,080 Implemented
SD0051 # 08 Y:1993 08 1993 USE PHOTOCELL CONTROLS $907 $1,715 Not Implemented
OR0133 # 01 Y:1991 01 1991 INSTALL SET-BACK TIMERS $1,035 $0 Implemented
OR0133 # 02 Y:1991 02 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $117 $0 Implemented
OR0133 # 03 Y:1991 03 1991 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,152 $1,000 Implemented
OR0133 # 04 Y:1991 04 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $35,000 $30,500 Implemented
OR0133 # 05 Y:1991 05 1991 OPTIMIZE PLANT POWER FACTOR $6,809 $15,000 Implemented
OR0133 # 06 Y:1991 06 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,637 $3,882 Implemented
OR0133 # 07 Y:1991 07 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $219 $850 Implemented
OR0134 # 01 Y:1991 01 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $655 $0 Not Implemented
OR0134 # 02 Y:1991 02 1991 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $3,960 $0 Not Implemented