IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

183

matching recommendations
Reset
SIC 2653 Corrugated And Solid Fiber Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0041 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $604 $350 Implemented
LM0041 # 02 Y:2002 02 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,833 $100 Implemented
LM0041 # 03 Y:2002 03 2002 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $6,250 $1,000 Not Implemented
LM0041 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $122,392 $68,248 Not Implemented
LM0041 # 05 Y:2002 05 2002 $612,000 $1,100,000 Not Implemented
LM0041 # 06 Y:2002 06 2002 $93,750 $24,000 Implemented
LM0041 # 07 Y:2002 07 2002 $228,000 $1,000 Implemented
SF0237 # 01 Y:2002 01 2002 REPAIR AND ELIMINATE STEAM LEAKS $7,124 $0 Implemented
SF0237 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,874 $0 Implemented
SF0237 # 03 Y:2002 03 2002 INSTALL OCCUPANCY SENSORS $4,283 $960 Not Implemented
SF0237 # 04 Y:2002 04 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,539 $1,024 Implemented
SF0237 # 05 Y:2002 05 2002 INSULATE BARE EQUIPMENT $8,315 $6,667 Implemented
SF0237 # 06 Y:2002 06 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $11,732 $16,065 Not Implemented
SF0237 # 07 Y:2002 07 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,405 $58,318 Implemented
SF0237 # 08 Y:2002 08 2002 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $210 $627 Not Implemented
SF0237 # 09 Y:2002 09 2002 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $3,489 $0 Implemented
SF0237 # 10 Y:2002 10 2002 OPTIMIZE PLANT POWER FACTOR $4,500 $5,806 Not Implemented
SF0233 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,975 $0 Implemented
SF0233 # 02 Y:2002 02 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $450 $890 Not Implemented
SF0132 # 01 Y:1998 01 1998 SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE $1,548 $488 Not Implemented
SF0132 # 02 Y:1998 02 1998 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $4,201 $0 Implemented
SF0132 # 03 Y:1998 03 1998 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $20,620 $2,065 Not Implemented
SF0132 # 04 Y:1998 04 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,354 $1,650 Implemented
SF0132 # 05 Y:1998 05 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,412 $26,680 Not Implemented
SF0132 # 06 Y:1998 06 1998 OPTIMIZE PLANT POWER FACTOR $2,725 $4,531 Not Implemented