Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
343
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0503 # 02 Y:2002 | 02 | 2002 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $25,940 | $0 | Implemented |
CO0503 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,053 | $0 | Not Implemented |
CO0503 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,310 | $430 | Implemented |
CO0503 # 05 Y:2002 | 05 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,730 | $870 | Not Implemented |
CO0503 # 08 Y:2002 | 08 | 2002 | USE PHOTOCELL CONTROLS | $2,160 | $2,040 | Not Implemented |
CO0503 # 07 Y:2002 | 07 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $498 | $946 | Implemented |
CO0503 # 06 Y:2002 | 06 | 2002 | INSTALL OCCUPANCY SENSORS | $2,760 | $3,360 | Not Implemented |
CO0424 # 01 Y:1998 | 01 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,580 | $1,000 | Not Implemented |
CO0424 # 02 Y:1998 | 02 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $5,030 | $450 | Not Implemented |
CO0423 # 01 Y:1998 | 01 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $850 | $1,000 | Not Implemented |
CO0423 # 07 Y:1998 | 07 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $2,350 | $6,900 | Implemented |
CO0423 # 02 Y:1998 | 02 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $140 | $420 | Implemented |
CO0423 # 03 Y:1998 | 03 | 1998 | MINIMIZE WATER USAGE | $9,100 | $11,210 | Implemented |
CO0423 # 04 Y:1998 | 04 | 1998 | SEPARATE TREATMENTS FOR EACH TYPE OF SOLUTION AND RECYCLE | $8,870 | $2,500 | Implemented |
CO0423 # 05 Y:1998 | 05 | 1998 | ALLOW DRAINAGE BEFORE WITHDRAWING OBJECT | $4,550 | $2,000 | Implemented |
CO0423 # 06 Y:1998 | 06 | 1998 | SEPARATE TREATMENTS FOR EACH TYPE OF SOLUTION AND RECYCLE | $2,580 | $25,000 | Implemented |
CO0419 # 01 Y:1998 | 01 | 1998 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,930 | $6,000 | Not Implemented |
CO0419 # 05 Y:1998 | 05 | 1998 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $19,614 | $27,000 | Not Implemented |
CO0419 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $350 | $350 | Not Implemented |
CO0419 # 03 Y:1998 | 03 | 1998 | CONSIDER POWER LOSS AS WELL AS INITIAL LOADS AND LOAD GROWTH IN DOWN-SIZING TRANSFORMERS | $2,170 | $2,820 | Not Implemented |
CO0419 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $3,400 | $1,120 | Not Implemented |
CO0412 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,288 | $6,148 | Not Implemented |
CO0412 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,694 | $9,850 | Implemented |
CO0412 # 03 Y:1998 | 03 | 1998 | DISCONNECT BALLASTS | $5,060 | $3,330 | Not Implemented |
CO0412 # 04 Y:1998 | 04 | 1998 | DISCONNECT BALLASTS | $1,230 | $900 | Implemented |