IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

206

matching recommendations
Reset
NAICS 312 Beverage and Tobacco Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0395 # 11 Y:2007 11 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,271 $0 Implemented
UF0395 # 12 Y:2007 12 2007 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $53,219 $20,339 Implemented
UF0395 # 13 Y:2007 13 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $180,645 $263,004 Implemented
UF0388 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,746 $4,846 Not Implemented
UF0388 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,378 $1,688 Not Implemented
UF0388 # 03 Y:2006 03 2006 INSTALL OCCUPANCY SENSORS $341 $342 Not Implemented
UF0388 # 04 Y:2006 04 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $922 $2,346 Not Implemented
UF0388 # 05 Y:2006 05 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $7,286 $1,238 Not Implemented
UF0388 # 06 Y:2006 06 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,957 $0 Not Implemented
UF0388 # 07 Y:2006 07 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $193 $374 Not Implemented
UF0388 # 08 Y:2006 08 2006 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,088 $93 Not Implemented
UF0388 # 09 Y:2006 09 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,663 $1,320 Not Implemented
UF0388 # 10 Y:2006 10 2006 USE PHOTOCELL CONTROLS $553 $240 Not Implemented
UF0388 # 11 Y:2006 11 2006 PREHEAT COMBUSTION AIR WITH WASTE HEAT $12,667 $65,000 Not Implemented
MI0137 # 01 Y:2006 01 2006 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $7,657 $600 Not Implemented
MI0137 # 02 Y:2006 02 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,436 $1,074 Implemented
MI0137 # 03 Y:2006 03 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,902 $30 Implemented
MI0137 # 04 Y:2006 04 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,327 $48 Implemented
MI0137 # 05 Y:2006 05 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,128 $175 Implemented
MI0137 # 06 Y:2006 06 2006 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $901 $3,400 Implemented
MI0137 # 07 Y:2006 07 2006 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $661 $2,809 Implemented
UF0369 # 01 Y:2005 01 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,002 $2,082 Implemented
UF0369 # 02 Y:2005 02 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,073 $460 Implemented
UF0369 # 03 Y:2005 03 2005 INSULATE BARE EQUIPMENT $21,928 $477 Implemented
UF0369 # 04 Y:2005 04 2005 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $0 $24,800 Implemented