Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
359
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0061 # 04 Y:2003 | 04 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,962 | $6 | Implemented |
MI0061 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $974 | $332 | Implemented |
MI0061 # 02 Y:2003 | 02 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,605 | $169 | Not Implemented |
MI0061 # 01 Y:2003 | 01 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,497 | $8,673 | Not Implemented |
MI0061 # 07 Y:2003 | 07 | 2003 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $27,760 | $2,808 | Not Implemented |
MI0060 # 04 Y:2003 | 04 | 2003 | REDUCE EXCESSIVE BOILER BLOWDOWN | $6,768 | $4,500 | Not Implemented |
MI0060 # 07 Y:2003 | 07 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $971 | $258 | Implemented |
MI0060 # 06 Y:2003 | 06 | 2003 | METER WASTE WATER | $36,908 | $1,950 | Implemented |
MI0060 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $943 | $1,792 | Not Implemented |
MI0060 # 03 Y:2003 | 03 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $49,692 | $22,500 | Not Implemented |
MI0060 # 02 Y:2003 | 02 | 2003 | REPAIR OR REPLACE STEAM TRAPS | $1,282 | $57 | Implemented |
MI0060 # 01 Y:2003 | 01 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,444 | $513 | Implemented |
UF0320 # 02 Y:2003 | 02 | 2003 | INSTALL SKYLIGHTS | $16,155 | $67,591 | Not Implemented |
UF0320 # 03 Y:2003 | 03 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $1,161 | $225 | Implemented |
UF0320 # 04 Y:2003 | 04 | 2003 | OPTIMIZE PLANT POWER FACTOR | $3,320 | $3,000 | Not Implemented |
UF0320 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $12,604 | $0 | Not Implemented |
UF0320 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,426 | $28,971 | Not Implemented |
UF0320 # 07 Y:2003 | 07 | 2003 | $70,120 | $150,000 | Not Implemented | |
UF0320 # 08 Y:2003 | 08 | 2003 | $7,009 | $4,000 | Implemented | |
UF0320 # 09 Y:2003 | 09 | 2003 | $448,198 | $37,200 | Implemented | |
UF0320 # 01 Y:2003 | 01 | 2003 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $25,707 | $48,985 | Implemented |
UF0317 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,161 | $11,978 | n/a |
UF0317 # 02 Y:2003 | 02 | 2003 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $4,254 | $1,640 | n/a |
UF0317 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,925 | $5,839 | n/a |
UF0317 # 04 Y:2003 | 04 | 2003 | OPTIMIZE PLANT POWER FACTOR | $5,621 | $15,000 | n/a |