Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
164
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0429 # 12 Y:2009 | 12 | 2009 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $16,025 | $0 | Not Implemented |
UF0429 # 11 Y:2009 | 11 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $14,435 | $0 | Not Implemented |
UF0429 # 10 Y:2009 | 10 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,346 | $0 | Not Implemented |
UF0429 # 09 Y:2009 | 09 | 2009 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $19,795 | $0 | Not Implemented |
UF0429 # 08 Y:2009 | 08 | 2009 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,119 | $0 | Not Implemented |
UF0429 # 07 Y:2009 | 07 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $45,514 | $0 | Not Implemented |
UF0429 # 06 Y:2009 | 06 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,625 | $0 | Not Implemented |
UF0429 # 01 Y:2009 | 01 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,635 | $0 | Implemented |
UF0429 # 03 Y:2009 | 03 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,130 | $0 | Not Implemented |
UF0429 # 13 Y:2009 | 13 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $42,269 | $0 | Implemented |
UF0429 # 14 Y:2009 | 14 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $68,295 | $0 | Not Implemented |
UF0429 # 05 Y:2009 | 05 | 2009 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $334 | $0 | Implemented |
UF0429 # 04 Y:2009 | 04 | 2009 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,899 | $0 | Not Implemented |
UF0429 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,766 | $0 | Implemented |
UF0428 # 07 Y:2009 | 07 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,285 | $0 | Implemented |
UF0428 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,365 | $0 | Implemented |
UF0428 # 06 Y:2009 | 06 | 2009 | INSTALL COMMON HEADER ON COMPRESSORS | $674 | $0 | Not Implemented |
UF0428 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,980 | $5,895 | Implemented |
UF0428 # 05 Y:2009 | 05 | 2009 | INSTALL OCCUPANCY SENSORS | $872 | $1,971 | Implemented |
UF0428 # 01 Y:2009 | 01 | 2009 | MINIMIZE USE OF RAGS THROUGH WORKER TRAINING | $1,734 | $0 | Implemented |
UF0428 # 08 Y:2009 | 08 | 2009 | OPTIMIZE PLANT POWER FACTOR | $44,818 | $3,326 | Not Implemented |
UF0428 # 09 Y:2009 | 09 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $25,086 | $0 | Implemented |
UF0428 # 04 Y:2009 | 04 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,371 | $2,260 | Not Implemented |
MI0186 # 05 Y:2009 | 05 | 2009 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $24,293 | $1,600 | Not Implemented |
MI0186 # 03 Y:2009 | 03 | 2009 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $76,266 | $28,000 | Not Implemented |