Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

309

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0099 # 02 Y:2005 02 2005 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $16,520 $7,062 Not Implemented
MI0099 # 03 Y:2005 03 2005 UPGRADE CONTROLS ON COMPRESSORS $11,973 $2,750 Implemented
MI0099 # 04 Y:2005 04 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $8,746 $4,736 Not Implemented
MI0099 # 05 Y:2005 05 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,897 $470 Implemented
MI0099 # 06 Y:2005 06 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,355 $1,750 Implemented
MI0099 # 07 Y:2005 07 2005 USE MINIMUM STEAM OPERATING PRESSURE $200 $115 Implemented
UF0356 # 01 Y:2005 01 2005 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $0 $150,000 Not Implemented
UF0356 # 02 Y:2005 02 2005 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $11,843 $21,108 Implemented
UF0356 # 03 Y:2005 03 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $6,348 $2,000 Implemented
UF0356 # 04 Y:2005 04 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,008 $700 Implemented
UF0356 # 05 Y:2005 05 2005 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $2,918 $1,185 Not Implemented
UF0356 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,295 $2,194 Implemented
UF0356 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $1,232 $1,450 Implemented
UF0356 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $96 $245 Implemented
UF0356 # 09 Y:2005 09 2005 RECYCLE FLUORESCENT LAMPS $0 $3,496 Implemented
MI0098 # 01 Y:2005 01 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $24,731 $1,000 Implemented
MI0098 # 02 Y:2005 02 2005 $7,463 $111 Implemented
MI0098 # 03 Y:2005 03 2005 $4,950 $1,910 Implemented
MI0098 # 04 Y:2005 04 2005 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $2,754 $4,360 Not Implemented
MI0098 # 05 Y:2005 05 2005 REPAIR AND ELIMINATE STEAM LEAKS $901 $380 Implemented
MI0098 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $301 $400 Implemented
UF0355 # 01 Y:2005 01 2005 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $14,486 $80,890 Implemented
UF0355 # 02 Y:2005 02 2005 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $21,072 $93,200 Implemented
UF0355 # 03 Y:2005 03 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,438 $478 Implemented
UF0355 # 04 Y:2005 04 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $23,786 $0 Not Implemented