Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0214 # 03 Y:1984 | 03 | 1984 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $7,406 | $10,000 | Implemented |
GT0217 # 06 Y:1984 | 06 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,670 | $640 | Implemented |
GT0217 # 05 Y:1984 | 05 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $19,960 | $1,000 | Implemented |
GT0214 # 01 Y:1984 | 01 | 1984 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,957 | $15,000 | Implemented |
GT0215 # 01 Y:1984 | 01 | 1984 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $11,255 | $24,000 | Implemented |
GT0214 # 02 Y:1984 | 02 | 1984 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $1,493 | $2,000 | Implemented |
GT0211 # 07 Y:1984 | 07 | 1984 | BURN A LESS EXPENSIVE GRADE OF FUEL | $67,362 | $200,000 | Implemented |
GT0211 # 05 Y:1984 | 05 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $335 | $148 | Implemented |
GT0211 # 06 Y:1984 | 06 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $808 | $104 | Implemented |
GT0211 # 08 Y:1984 | 08 | 1984 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,000 | $8,000 | Implemented |
GT0207 # 03 Y:1984 | 03 | 1984 | INSTALL SET-BACK TIMERS | $1,187 | $0 | Implemented |
GT0210 # 01 Y:1984 | 01 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,560 | $800 | Implemented |
GT0210 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,820 | $1,850 | Implemented |
GT0212 # 01 Y:1984 | 01 | 1984 | REPLACE BOILER | $8,550 | $25,000 | Implemented |
GT0212 # 02 Y:1984 | 02 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $2,540 | $250 | Implemented |
GT0212 # 03 Y:1984 | 03 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $334 | $192 | Implemented |
GT0212 # 04 Y:1984 | 04 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,069 | $145 | Implemented |
GT0212 # 05 Y:1984 | 05 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $739 | $861 | Implemented |
GT0211 # 04 Y:1984 | 04 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $985 | $432 | Implemented |
GT0211 # 03 Y:1984 | 03 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $300 | $50 | Implemented |
GT0211 # 02 Y:1984 | 02 | 1984 | COVER OPEN TANKS | $2,894 | $4,000 | Implemented |
GT0211 # 01 Y:1984 | 01 | 1984 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $19,964 | $32,000 | Implemented |
GT0208 # 06 Y:1984 | 06 | 1984 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $18,300 | $20,000 | Implemented |
GT0206 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,815 | $200 | Implemented |
GT0206 # 03 Y:1984 | 03 | 1984 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $14,224 | $9,000 | Implemented |