IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

81

matching recommendations
Reset
SIC 204 Grain Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0296 # 05 Y:2002 05 2002 INSTALL OCCUPANCY SENSORS $341 $466 Not Implemented
IA0296 # 04 Y:2002 04 2002 REPAIR OR REPLACE STEAM TRAPS $5,180 $1,320 Implemented
IA0296 # 03 Y:2002 03 2002 REPAIR AND ELIMINATE STEAM LEAKS $5,317 $1,800 Implemented
IA0296 # 02 Y:2002 02 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,082 $586 Not Implemented
IA0178 # 01 Y:1997 01 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,051 $1,100 Implemented
IA0178 # 07 Y:1997 07 1997 IMPROVE HANDLING PRACTICES $91,000 $4,500 Implemented
IA0178 # 06 Y:1997 06 1997 RECOVER AND REUSE COOLING WATER $3,700 $5,453 Implemented
IA0178 # 05 Y:1997 05 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $2,100 $8,100 Implemented
IA0178 # 04 Y:1997 04 1997 INSTALL OCCUPANCY SENSORS $166 $630 Not Implemented
IA0178 # 03 Y:1997 03 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $538 $50 Implemented
IA0178 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,223 $1,915 Implemented
DS0044 # 07 Y:1995 07 1995 RECOVER WASTE HEAT FROM EQUIPMENT $1,035 $2,000 Not Implemented
DS0044 # 08 Y:1995 08 1995 INSULATE BARE EQUIPMENT $168 $263 Not Implemented
DS0044 # 06 Y:1995 06 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $135 $135 Implemented
DS0044 # 05 Y:1995 05 1995 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $504 $290 Not Implemented
DS0044 # 04 Y:1995 04 1995 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,652 $170 Implemented
DS0044 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,828 $15,870 Implemented
DS0044 # 02 Y:1995 02 1995 INSTALL OCCUPANCY SENSORS $570 $400 Implemented
DS0044 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,508 $4,325 Implemented
IA0069 # 05 Y:1993 05 1993 RECOVER WASTE HEAT FROM EQUIPMENT $637 $1,700 Not Implemented
IA0069 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $720 $0 Implemented
IA0069 # 03 Y:1993 03 1993 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $13,911 $2,500 Implemented
IA0069 # 02 Y:1993 02 1993 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $62,688 $80,010 Not Implemented
IA0069 # 01 Y:1993 01 1993 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST $363,236 $1,064,000 Not Implemented
IA0069 # 04 Y:1993 04 1993 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $2,716 $1,040 Implemented