Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

202

matching recommendations
Reset
SIC 3089 Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0267 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,910 $120 Implemented
IA0267 # 02 Y:2001 02 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,711 $2,000 Implemented
IA0267 # 03 Y:2001 03 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,261 $65 Not Implemented
IA0267 # 04 Y:2001 04 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,199 $0 Not Implemented
IA0267 # 05 Y:2001 05 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,590 $4,978 Not Implemented
IA0267 # 06 Y:2001 06 2001 INSTALL OCCUPANCY SENSORS $571 $1,397 Not Implemented
IA0267 # 07 Y:2001 07 2001 $511,200 $300,000 Not Implemented
IA0267 # 08 Y:2001 08 2001 $127,800 $107,000 Not Implemented
IA0267 # 09 Y:2001 09 2001 $18,225 $42,125 Not Implemented
IA0267 # 10 Y:2001 10 2001 $10,872 $7,000 Not Implemented
IA0219 # 01 Y:1999 01 1999 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $9,876 $1,788 Not Implemented
IA0219 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,956 $195 Not Implemented
IA0219 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,239 $0 Not Implemented
IA0219 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,916 $25 Not Implemented
IA0219 # 05 Y:1999 05 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,383 $5,695 Not Implemented
IA0219 # 06 Y:1999 06 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,373 $246 Not Implemented
IA0219 # 07 Y:1999 07 1999 INSTALL OCCUPANCY SENSORS $237 $1,197 Not Implemented
IA0219 # 08 Y:1999 08 1999 MINIMIZE WATER USAGE $95,331 $50 Not Implemented
IA0219 # 09 Y:1999 09 1999 $254,475 $511,800 Not Implemented
IA0219 # 10 Y:1999 10 1999 $28,975 $132 Not Implemented
IA0207 # 01 Y:1998 01 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $109,522 $345,000 Not Implemented
IA0207 # 02 Y:1998 02 1998 $46,000 $12,000 Not Implemented
IA0207 # 03 Y:1998 03 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,193 $1,348 Implemented
IA0207 # 04 Y:1998 04 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $4,781 $4,185 Implemented
IA0207 # 05 Y:1998 05 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,212 $82 Implemented