Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
34
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0466 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $220 | $0 | Not Implemented |
OR0466 # 02 Y:2004 | 02 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,250 | $330 | Not Implemented |
OR0466 # 01 Y:2004 | 01 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,000 | $21,000 | Implemented |
OR0465 # 05 Y:2004 | 05 | 2004 | OPTIMIZE PLANT POWER FACTOR | $35,600 | $55,000 | Implemented |
OR0465 # 04 Y:2004 | 04 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $8,200 | $5,000 | Not Implemented |
OR0465 # 03 Y:2004 | 03 | 2004 | MOVE PRODUCT USING MECHANICAL MEANS | $426,000 | $4,000 | Not Implemented |
OR0465 # 02 Y:2004 | 02 | 2004 | INCREASE AMOUNT OF CONDENSATE RETURNED | $46,600 | $14,000 | Implemented |
OR0465 # 01 Y:2004 | 01 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $8,400 | $0 | Implemented |
OR0465 # 06 Y:2004 | 06 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,200 | $13,400 | Implemented |
OR0465 # 07 Y:2004 | 07 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,195 | $2,800 | Implemented |
OR0464 # 03 Y:2004 | 03 | 2004 | INSTALL AUTOMATIC PACKING EQUIPMENT | $35,405 | $42,000 | Not Implemented |
OR0464 # 04 Y:2004 | 04 | 2004 | INSTALL BACK-UP EQUIPMENT | $44,800 | $170 | Implemented |
OR0464 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,300 | $6,900 | Implemented |
OR0464 # 06 Y:2004 | 06 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,000 | $800 | Not Implemented |
OR0464 # 02 Y:2004 | 02 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $5,200 | $0 | Implemented |
OR0464 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,350 | $1,350 | Implemented |
OR0463 # 02 Y:2004 | 02 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $3,700 | $0 | Implemented |
OR0463 # 05 Y:2004 | 05 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $73,800 | $600 | Implemented |
OR0463 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,000 | $10,000 | Implemented |
OR0463 # 03 Y:2004 | 03 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $26,000 | $22,920 | Not Implemented |
OR0463 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,060 | $3,000 | Implemented |
OR0463 # 06 Y:2004 | 06 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $9,400 | $1,000 | Not Implemented |
UU0067 # 06 Y:2004 | 06 | 2004 | TREAT AND REUSE RINSE WATERS | $635,880 | $1,705,000 | Not Implemented |
UU0067 # 05 Y:2004 | 05 | 2004 | INSTALL WIND POWERED ELECTRIC GENERATOR | $0 | $40,000 | Not Implemented |
UU0067 # 04 Y:2004 | 04 | 2004 | INSTALL WIND POWERED ELECTRIC GENERATOR | $0 | $0 | Implemented |