IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

149

matching recommendations
Reset
NAICS 3327 Machine Shops; Turned Product; and Screw, Nut, and Bolt Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0353 # 08 Y:2008 08 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,315 $3,150 Not Implemented
BD0353 # 09 Y:2008 09 2008 USE EVAPORATION TO CONCENTRATE MATERIAL $6,150 $7,400 Not Implemented
BD0348 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,613 $24,066 Not Implemented
BD0348 # 02 Y:2008 02 2008 INSTALL OCCUPANCY SENSORS $1,392 $2,026 Not Implemented
BD0348 # 03 Y:2008 03 2008 RECOVER WASTE HEAT FROM EQUIPMENT $9,758 $2,001 Not Implemented
BD0348 # 04 Y:2008 04 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,081 $2 Not Implemented
BD0348 # 05 Y:2008 05 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $142,941 $1,401 Not Implemented
BD0348 # 06 Y:2008 06 2008 USE RADIANT HEATER FOR SPOT HEATING $7,689 $5,001 Not Implemented
BD0348 # 07 Y:2008 07 2008 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $50,882 $42,001 Not Implemented
BD0348 # 08 Y:2008 08 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,743 $7,844 Not Implemented
BD0348 # 09 Y:2008 09 2008 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $54,402 $12,001 Not Implemented
BD0348 # 10 Y:2008 10 2008 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $31,164 $7,000 Not Implemented
BD0347 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $51,977 $120 Implemented
BD0347 # 02 Y:2008 02 2008 INSTALL OCCUPANCY SENSORS $4,457 $5,400 Implemented
BD0347 # 03 Y:2008 03 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,032 $2 Not Implemented
BD0347 # 04 Y:2008 04 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $9,195 $501 Not Implemented
BD0347 # 05 Y:2008 05 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $41,601 $43,021 Not Implemented
BD0347 # 06 Y:2008 06 2008 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $898 $2,101 Not Implemented
BD0347 # 07 Y:2008 07 2008 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,228 $257 Not Implemented
BD0347 # 08 Y:2008 08 2008 USE EVAPORATION TO CONCENTRATE MATERIAL $5,997 $7,996 Not Implemented
BD0265 # 01 Y:2004 01 2004 USE RADIANT HEATER FOR SPOT HEATING $27,949 $4,200 Not Implemented
BD0265 # 02 Y:2004 02 2004 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $3,335 $20,000 Not Implemented
BD0265 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,398 $2,861 Not Implemented
BD0265 # 04 Y:2004 04 2004 USE SYNTHETIC LUBRICANT $4,332 $1,650 Not Implemented
BD0265 # 05 Y:2004 05 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,701 $1,200 Not Implemented