Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
356
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0072 # 01 Y:2016 | 01 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $935 | $0 | Implemented |
IP0058 # 01 Y:2016 | 01 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,007 | $326 | Not Implemented |
IP0058 # 02 Y:2016 | 02 | 2016 | INSTALL OCCUPANCY SENSORS | $256 | $51 | Not Implemented |
IP0058 # 03 Y:2016 | 03 | 2016 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $30,281 | $6,819 | Not Implemented |
IP0058 # 04 Y:2016 | 04 | 2016 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $11,137 | $4,626 | Not Implemented |
IP0058 # 05 Y:2016 | 05 | 2016 | USE MAGNETIC TECHNOLOGY TO TREAT WATER | $227 | $255 | Not Implemented |
IP0058 # 06 Y:2016 | 06 | 2016 | OPTIMIZE PLANT POWER FACTOR | $46,574 | $102,745 | Not Implemented |
IP0046 # 01 Y:2015 | 01 | 2015 | UPGRADE OBSOLETE EQUIPMENT | $1,665 | $4 | Not Implemented |
IP0046 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,302 | $64 | Not Implemented |
IP0046 # 03 Y:2015 | 03 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $122 | $117 | Not Implemented |
IP0046 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,526 | $4,032 | Not Implemented |
IP0046 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $348 | $512 | Not Implemented |
IP0046 # 06 Y:2015 | 06 | 2015 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $6,619 | $10,141 | Not Implemented |
IP0045 # 05 Y:2015 | 05 | 2015 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,201 | $17,250 | Implemented |
IP0045 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,242 | $417 | Implemented |
IP0045 # 03 Y:2015 | 03 | 2015 | BURN A LESS EXPENSIVE GRADE OF FUEL | $25,783 | $1,054 | Implemented |
IP0045 # 02 Y:2015 | 02 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $401 | $0 | Implemented |
IP0045 # 01 Y:2015 | 01 | 2015 | APPLY FOR INVESTMENT INCENTIVES | $1,605 | $0 | Implemented |
IP0015 # 01 Y:2013 | 01 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,644 | $0 | Implemented |
IP0015 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,757 | $0 | Not Implemented |
IP0015 # 03 Y:2013 | 03 | 2013 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $730 | $0 | Not Implemented |
IP0015 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $1,044 | $118 | Not Implemented |
IP0015 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,010 | $1,400 | Implemented |
IP0015 # 06 Y:2013 | 06 | 2013 | INSULATE BARE EQUIPMENT | $7,093 | $380 | Implemented |
IP0015 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,795 | $8,625 | Implemented |