IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

56

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0853 # 07 Y:2013 07 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,264 $12,032 Not Implemented
OK0853 # 02 Y:2013 02 2013 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $5,649 $4,550 Not Implemented
OK0853 # 01 Y:2013 01 2013 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $26,647 $7,150 Not Implemented
OK0853 # 04 Y:2013 04 2013 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $4,173 $240 Implemented
OK0853 # 06 Y:2013 06 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $763 $5,865 Not Implemented
OK0853 # 03 Y:2013 03 2013 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $4,083 $15,925 Not Implemented
OK0853 # 05 Y:2013 05 2013 USE RADIANT HEATER FOR SPOT HEATING $6,694 $16,250 Not Implemented
OK0853 # 08 Y:2013 08 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,210 $300 Implemented
OK0853 # 09 Y:2013 09 2013 OPTIMIZE PLANT POWER FACTOR $3,767 $7,526 Not Implemented
OK0847 # 04 Y:2013 04 2013 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $1,473 $1,128 Implemented
OK0847 # 02 Y:2013 02 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $623 $180 Implemented
OK0847 # 03 Y:2013 03 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,698 $29,880 Implemented
OK0847 # 05 Y:2013 05 2013 USE RADIANT HEATER FOR SPOT HEATING $13,014 $32,500 Not Implemented
OK0847 # 06 Y:2013 06 2013 OPTIMIZE PLANT POWER FACTOR $12,719 $11,540 Not Implemented
OK0847 # 01 Y:2013 01 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,232 $0 Not Implemented
OK0846 # 03 Y:2013 03 2013 INSTALL OCCUPANCY SENSORS $1,618 $31,000 Not Implemented
OK0846 # 09 Y:2013 09 2013 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $493 $413 Implemented
OK0846 # 08 Y:2013 08 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $2,202 $862 Implemented
OK0846 # 07 Y:2013 07 2013 OPTIMIZE PLANT POWER FACTOR $32,267 $17,174 Implemented
OK0846 # 06 Y:2013 06 2013 RECOVER WASTE HEAT FROM EQUIPMENT $5,061 $3,840 Implemented
OK0846 # 05 Y:2013 05 2013 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,467 $13,650 Implemented
OK0846 # 02 Y:2013 02 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,561 $525 Implemented
OK0846 # 04 Y:2013 04 2013 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $7,018 $8,775 Not Implemented
OK0846 # 01 Y:2013 01 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,801 $9,541 Not Implemented
OK0845 # 02 Y:2013 02 2013 INSTALL OCCUPANCY SENSORS $90 $366 Not Implemented