Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

92

matching recommendations
Reset
SIC 308 Miscellaneous Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0405 # 11 Y:2010 11 2010 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $194 $0 Not Implemented
WV0271 # 07 Y:2003 07 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $3,967 $1,741 Not Implemented
WV0271 # 13 Y:2003 13 2003 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $160 $32 Implemented
WV0271 # 12 Y:2003 12 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $140 $132 Not Implemented
WV0271 # 11 Y:2003 11 2003 INSTALL OCCUPANCY SENSORS $839 $800 Implemented
WV0271 # 10 Y:2003 10 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,758 $0 Implemented
WV0271 # 09 Y:2003 09 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,425 $250 Implemented
WV0271 # 08 Y:2003 08 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,612 $800 Not Implemented
WV0271 # 06 Y:2003 06 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $4,697 $32 Not Implemented
WV0271 # 04 Y:2003 04 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $13,169 $500 Not Implemented
WV0271 # 03 Y:2003 03 2003 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM $36,152 $180,000 Not Implemented
WV0271 # 02 Y:2003 02 2003 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $27,875 $480 Implemented
WV0271 # 01 Y:2003 01 2003 INSULATE BARE EQUIPMENT $76,401 $2,253 Implemented
WV0271 # 05 Y:2003 05 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,764 $128 Implemented
WV0052 # 05 Y:1995 05 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,025 $2,534 Implemented
WV0052 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $400 $350 Implemented
WV0052 # 03 Y:1995 03 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,204 $6,600 Implemented
WV0052 # 02 Y:1995 02 1995 RECOVER WASTE HEAT FROM EQUIPMENT $861 $1,130 Not Implemented
WV0052 # 01 Y:1995 01 1995 OPTIMIZE PLANT POWER FACTOR $9,329 $5,737 Not Implemented
WV0051 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,399 $3,964 Implemented
WV0051 # 01 Y:1995 01 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $21,730 $9,819 Not Implemented
WV0051 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,413 $1,130 Implemented
WV0051 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,330 $30,260 Implemented
WV0051 # 06 Y:1995 06 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $41,711 $1,550 Not Implemented
WV0051 # 07 Y:1995 07 1995 INSULATE BARE EQUIPMENT $890 $1,508 Not Implemented