Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

30

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0304 # 05 Y:2000 05 2000 $29,835 $4,434 Implemented
ME0304 # 04 Y:2000 04 2000 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $1,848 $0 Implemented
ME0304 # 03 Y:2000 03 2000 INSTALL / REPAIR INSULATION ON STEAM LINES $152 $384 Not Implemented
ME0304 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,300 $3,542 Not Implemented
ME0304 # 01 Y:2000 01 2000 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,601 $3,600 Not Implemented
ME0299 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,184 $14,916 Not Implemented
ME0299 # 11 Y:2000 11 2000 $7,500 $6,043 Not Implemented
ME0299 # 10 Y:2000 10 2000 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $197 $240 Not Implemented
ME0299 # 08 Y:2000 08 2000 INSULATE FEEDWATER TANK $412 $80 Not Implemented
ME0299 # 07 Y:2000 07 2000 PAY UTILITY BILLS ON TIME $484 $0 Not Implemented
ME0299 # 06 Y:2000 06 2000 INSTALL / REPAIR INSULATION ON STEAM LINES $820 $1,637 Not Implemented
ME0299 # 05 Y:2000 05 2000 COMBINE UTILITY METERS $1,333 $3,910 Not Implemented
ME0299 # 04 Y:2000 04 2000 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,337 $2,440 Not Implemented
ME0299 # 03 Y:2000 03 2000 RECOVER WASTE HEAT FROM EQUIPMENT $4,620 $13,380 Not Implemented
ME0299 # 01 Y:2000 01 2000 CONVERT COMBUSTION EQUIPMENT TO BURN OIL $8,563 $9,360 Not Implemented
ME0299 # 09 Y:2000 09 2000 IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) $87,478 $8,500 Not Implemented
ME0290 # 02 Y:2000 02 2000 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $48,618 $10,860 Not Implemented
ME0290 # 08 Y:2000 08 2000 $26,063 $13,600 Implemented
ME0290 # 07 Y:2000 07 2000 $74,857 $270,000 Not Implemented
ME0290 # 06 Y:2000 06 2000 REUSE / RECYCLE/ SELL PAPER PRODUCTS $4,750 $9,000 Not Implemented
ME0290 # 05 Y:2000 05 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,685 $2,475 Implemented
ME0290 # 04 Y:2000 04 2000 RECOVER WASTE HEAT FROM EQUIPMENT $1,690 $5,000 Implemented
ME0290 # 03 Y:2000 03 2000 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $2,732 $1,800 Implemented
ME0290 # 01 Y:2000 01 2000 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $59,165 $59,168 Not Implemented
ME0289 # 01 Y:2000 01 2000 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $66,856 $175,000 Not Implemented