Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
154
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0234 # 01 Y:1998 | 01 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $38,400 | $50,000 | Implemented |
ME0234 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,284 | $800 | Implemented |
ME0234 # 02 Y:1998 | 02 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $19,979 | $12,932 | Implemented |
ME0234 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,153 | $10,580 | Implemented |
ME0234 # 07 Y:1998 | 07 | 1998 | RECOVER AND REUSE COOLING WATER | $12,512 | $12,000 | Implemented |
ME0234 # 09 Y:1998 | 09 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,887 | $3,000 | Not Implemented |
ME0234 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,482 | $4,476 | Implemented |
ME0234 # 10 Y:1998 | 10 | 1998 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $1,114 | $7,000 | Implemented |
ME0234 # 06 Y:1998 | 06 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $975 | $500 | Implemented |
ME0234 # 08 Y:1998 | 08 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $150 | $0 | Not Implemented |
ME0246 # 03 Y:1998 | 03 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,928 | $0 | Implemented |
ME0246 # 02 Y:1998 | 02 | 1998 | USE OPTIMUM TEMPERATURE | $7,462 | $0 | Implemented |
ME0246 # 05 Y:1998 | 05 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,568 | $0 | Implemented |
ME0246 # 04 Y:1998 | 04 | 1998 | INSULATE BARE EQUIPMENT | $5,134 | $10,930 | Implemented |
ME0246 # 06 Y:1998 | 06 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $18,894 | $43,500 | Implemented |
ME0246 # 01 Y:1998 | 01 | 1998 | USE OPTIMUM TEMPERATURE | $8,238 | $0 | Not Implemented |
ME0245 # 05 Y:1998 | 05 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,051 | $2,000 | Implemented |
ME0245 # 04 Y:1998 | 04 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,127 | $3,000 | Implemented |
ME0245 # 06 Y:1998 | 06 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $895 | $700 | Implemented |
ME0245 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,398 | $400 | Implemented |
ME0245 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,163 | $5,970 | Implemented |
ME0245 # 01 Y:1998 | 01 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,696 | $0 | Implemented |
ME0247 # 08 Y:1998 | 08 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $3,330 | $1,251 | Not Implemented |
ME0245 # 07 Y:1998 | 07 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $803 | $900 | Implemented |
ME0245 # 08 Y:1998 | 08 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $769 | $2,250 | Not Implemented |