Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
176
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0367 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,074 | $37,268 | Implemented |
UM0367 # 04 Y:2010 | 04 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,913 | $2,000 | Implemented |
UM0367 # 06 Y:2010 | 06 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $27,997 | $68,395 | Implemented |
UM0367 # 07 Y:2010 | 07 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $17,317 | $9,800 | Implemented |
UM0367 # 08 Y:2010 | 08 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,939 | $500 | Implemented |
UM0367 # 11 Y:2010 | 11 | 2010 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,186 | $7,500 | Implemented |
UM0367 # 13 Y:2010 | 13 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $277 | $329 | Implemented |
UM0367 # 14 Y:2010 | 14 | 2010 | INSTALL STORM WINDOWS AND DOORS | $171 | $1,400 | Implemented |
UM0366 # 04 Y:2010 | 04 | 2010 | INSULATE BARE EQUIPMENT | $2,117 | $596 | Implemented |
UM0366 # 05 Y:2010 | 05 | 2010 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $85 | $31 | Implemented |
UM0358 # 01 Y:2009 | 01 | 2009 | ISOLATE HOT OR COLD EQUIPMENT | $21,998 | $720 | Implemented |
UM0358 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,988 | $23,603 | Implemented |
UM0358 # 05 Y:2009 | 05 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $69 | $62 | Implemented |
UM0358 # 06 Y:2009 | 06 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $44,552 | $36,000 | Implemented |
UM0358 # 07 Y:2009 | 07 | 2009 | INSULATE BARE EQUIPMENT | $5,125 | $11,770 | Implemented |
UM0357 # 01 Y:2009 | 01 | 2009 | INSTALL STORM WINDOWS AND DOORS | $88,261 | $361,980 | Implemented |
UM0357 # 02 Y:2009 | 02 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $48,733 | $25,000 | Implemented |
UM0357 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,053 | $42,818 | Implemented |
UM0357 # 04 Y:2009 | 04 | 2009 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $5,524 | $2,591 | Implemented |
UM0357 # 05 Y:2009 | 05 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,523 | $1,359 | Implemented |
UM0357 # 06 Y:2009 | 06 | 2009 | INSTALL OCCUPANCY SENSORS | $1,466 | $4,692 | Implemented |
UM0357 # 07 Y:2009 | 07 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,875 | $7,500 | Implemented |
IC0163 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $528 | $332 | Implemented |
IC0163 # 02 Y:2009 | 02 | 2009 | INSTALL OCCUPANCY SENSORS | $635 | $538 | Implemented |
IC0163 # 03 Y:2009 | 03 | 2009 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,314 | $102 | Implemented |