Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

402

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0286 # 06 Y:1989 06 1989 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $14,815 $20,000 Implemented
KU0286 # 07 Y:1989 07 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $204 $250 Implemented
KU0269 # 02 Y:1988 02 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,858 $0 Implemented
KU0269 # 03 Y:1988 03 1988 INSTALL TIMERS AND/OR THERMOSTATS $5,967 $5,600 Implemented
KU0269 # 06 Y:1988 06 1988 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $166 $0 Implemented
KU0260 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,030 $500 Implemented
KU0260 # 02 Y:1988 02 1988 INSULATE BARE EQUIPMENT $1,114 $1,550 Implemented
KU0260 # 03 Y:1988 03 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $21,888 $2,000 Implemented
KU0260 # 04 Y:1988 04 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,971 $0 Implemented
KU0260 # 06 Y:1988 06 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,642 $1,100 Implemented
KU0260 # 07 Y:1988 07 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,314 $250 Implemented
KU0231 # 02 Y:1987 02 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $847 $100 Implemented
KU0231 # 03 Y:1987 03 1987 INSTALL TIMERS AND/OR THERMOSTATS $809 $40 Implemented
KU0231 # 05 Y:1987 05 1987 IMPROVE LUBRICATION PRACTICES $424 $600 Implemented
KU0231 # 06 Y:1987 06 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $212 $120 Implemented
KU0231 # 07 Y:1987 07 1987 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $211 $0 Implemented
KU0231 # 09 Y:1987 09 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $-79 $0 Implemented
KU0228 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,815 $14,465 Implemented
KU0228 # 03 Y:1987 03 1987 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $7,841 $0 Implemented
KU0228 # 04 Y:1987 04 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,401 $700 Implemented
KU0228 # 05 Y:1987 05 1987 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $1,064 $0 Implemented
KU0228 # 07 Y:1987 07 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $919 $1,700 Implemented
KU0228 # 09 Y:1987 09 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $153 $0 Implemented
KU0223 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,702 $1,847 Implemented
KU0223 # 03 Y:1987 03 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,201 $610 Implemented