Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

400

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0231 # 05 Y:1998 05 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $466 $90 Not Implemented
MO0231 # 06 Y:1998 06 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,184 $80 Not Implemented
MO0231 # 07 Y:1998 07 1998 USE SYNTHETIC LUBRICANT $261 $178 Not Implemented
MO0231 # 08 Y:1998 08 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $990 $1,872 Implemented
MO0231 # 09 Y:1998 09 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $205 $0 Implemented
MO0231 # 10 Y:1998 10 1998 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $1,947 $5,800 Implemented
KU0462 # 01 Y:1996 01 1996 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $28,125 $359 Implemented
KU0462 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,852 $312 Implemented
KU0462 # 03 Y:1996 03 1996 TREAT AND REUSE RINSE WATERS $6,559 $3,041 Implemented
KU0462 # 04 Y:1996 04 1996 INSTALL OCCUPANCY SENSORS $5,219 $1,450 Implemented
KU0462 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,755 $205 Implemented
KU0462 # 06 Y:1996 06 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,934 $2,566 Implemented
KU0462 # 07 Y:1996 07 1996 USE SYNTHETIC LUBRICANT $1,255 $299 Implemented
KU0462 # 08 Y:1996 08 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $393 $600 Not Implemented
KU0462 # 09 Y:1996 09 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $353 $42 Implemented
MO0151 # 01 Y:1995 01 1995 USE RADIANT HEATER FOR SPOT HEATING $27,601 $17,901 Not Implemented
MO0151 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,472 $15,370 Implemented
MO0151 # 03 Y:1995 03 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $530 $25 Not Implemented
MO0151 # 04 Y:1995 04 1995 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $9,918 $2,845 Not Implemented
MO0151 # 05 Y:1995 05 1995 USE PLASTIC PALLETS INSTEAD OF WOOD $38,520 $36,113 Not Implemented
KU0446 # 01 Y:1994 01 1994 CONVERT TO ELECTROSTATIC POWDER COATING $38,324 $12,000 Not Implemented
KU0446 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $18,466 $2,616 Not Implemented
KU0446 # 03 Y:1994 03 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $1,601 $1,600 Not Implemented
KU0446 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,291 $300 Implemented
KU0446 # 05 Y:1994 05 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,038 $10 Not Implemented