IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

76

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0268 # 06 Y:1988 06 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $153 $0 Implemented
KU0269 # 01 Y:1988 01 1988 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $17,859 $10,000 Not Implemented
KU0269 # 04 Y:1988 04 1988 INSTALL AUTOMATIC STACK DAMPER $243 $450 Not Implemented
KU0269 # 05 Y:1988 05 1988 RECOVER AND REUSE COOLING WATER $728 $0 Not Implemented
KU0269 # 06 Y:1988 06 1988 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $166 $0 Implemented
KU0269 # 02 Y:1988 02 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,858 $0 Implemented
KU0268 # 07 Y:1988 07 1988 IMPROVE LUBRICATION PRACTICES $153 $0 Implemented
KU0268 # 05 Y:1988 05 1988 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $664 $800 Not Implemented
KU0268 # 04 Y:1988 04 1988 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $563 $936 Not Implemented
KU0268 # 08 Y:1988 08 1988 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $1,598 $28 Implemented
KU0268 # 03 Y:1988 03 1988 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,831 $4,000 Not Implemented
KU0269 # 03 Y:1988 03 1988 INSTALL TIMERS AND/OR THERMOSTATS $5,967 $5,600 Implemented
KU0268 # 02 Y:1988 02 1988 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $3,098 $500 Implemented
KU0268 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,528 $8,010 Implemented
KU0262 # 05 Y:1988 05 1988 INSTALL / REPAIR INSULATION ON STEAM LINES $241 $400 Implemented
KU0262 # 03 Y:1988 03 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,009 $150 Implemented
KU0262 # 04 Y:1988 04 1988 INSTALL AUTOMATIC STACK DAMPER $340 $300 Not Implemented
KU0262 # 02 Y:1988 02 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,150 $250 Implemented
KU0262 # 01 Y:1988 01 1988 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $7,388 $500 Implemented
KU0260 # 05 Y:1988 05 1988 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $12,051 $0 Not Implemented
KU0261 # 04 Y:1988 04 1988 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $4,268 $2,000 Not Implemented
KU0261 # 05 Y:1988 05 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $743 $400 Not Implemented
KU0261 # 03 Y:1988 03 1988 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,957 $2,400 Not Implemented
KU0261 # 02 Y:1988 02 1988 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $7,119 $14,000 Not Implemented
KU0260 # 06 Y:1988 06 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,642 $1,100 Implemented