Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0325 # 04 Y:1990 | 04 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $1,788 | $2,802 | Not Implemented |
KU0325 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,200 | $3,078 | Implemented |
KU0325 # 01 Y:1990 | 01 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,128 | $20,800 | Not Implemented |
KU0322 # 04 Y:1990 | 04 | 1990 | INSTALL SET-BACK TIMERS | $2,494 | $900 | Implemented |
KU0322 # 03 Y:1990 | 03 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $653 | $250 | Implemented |
KU0322 # 02 Y:1990 | 02 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $16,055 | $4,500 | Implemented |
KU0322 # 01 Y:1990 | 01 | 1990 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $9,059 | $10,000 | Not Implemented |
KU0325 # 03 Y:1990 | 03 | 1990 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $391 | $466 | Implemented |
MO0010 # 05 Y:1990 | 05 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $565 | $150 | Implemented |
MO0010 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,455 | $921 | Implemented |
MO0010 # 04 Y:1990 | 04 | 1990 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,259 | $0 | Implemented |
MO0010 # 02 Y:1990 | 02 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,744 | $900 | Implemented |
MO0010 # 01 Y:1990 | 01 | 1990 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $11,076 | $1,932 | Implemented |
MO0009 # 05 Y:1990 | 05 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $248 | $0 | Implemented |
MO0009 # 04 Y:1990 | 04 | 1990 | RECOVER AND REUSE COOLING WATER | $671 | $129 | Implemented |
MO0009 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $227 | $125 | Implemented |
MO0009 # 02 Y:1990 | 02 | 1990 | INSULATE BARE EQUIPMENT | $2,555 | $1,085 | Not Implemented |
MO0009 # 01 Y:1990 | 01 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,849 | $382 | Not Implemented |
MO0008 # 06 Y:1990 | 06 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $171 | $0 | Not Implemented |
MO0008 # 05 Y:1990 | 05 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $735 | $319 | Implemented |
MO0006 # 03 Y:1990 | 03 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $698 | $0 | Implemented |
MO0007 # 02 Y:1990 | 02 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,118 | $15,000 | Not Implemented |
MO0007 # 01 Y:1990 | 01 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,971 | $900 | Implemented |
MO0007 # 03 Y:1990 | 03 | 1990 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $4,096 | $8,000 | Not Implemented |
MO0006 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $246 | $65 | Not Implemented |