Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0112 # 01 Y:2013 | 01 | 2013 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,737 | $19,304 | Not Implemented |
UA0112 # 05 Y:2013 | 05 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $1,143 | $520 | Not Implemented |
UA0112 # 03 Y:2013 | 03 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,177 | $878 | Implemented |
UA0112 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,385 | $2,330 | Implemented |
UA0112 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,965 | $49,792 | Not Implemented |
UA0101 # 06 Y:2013 | 06 | 2013 | REPLACE BOILER | $14,175 | $112,000 | Not Implemented |
UA0101 # 05 Y:2013 | 05 | 2013 | USE PHOTOCELL CONTROLS | $580 | $251 | Implemented |
UA0101 # 04 Y:2013 | 04 | 2013 | MINIMIZE WATER USAGE | $20,266 | $8,192 | Not Implemented |
UA0101 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,670 | $80 | Implemented |
UA0101 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,664 | $7,400 | Not Implemented |
UA0101 # 01 Y:2013 | 01 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $16,195 | $150 | Implemented |
UA0099 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $109,678 | $164,833 | Not Implemented |
UA0099 # 06 Y:2013 | 06 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,883 | $400 | Not Implemented |
UA0099 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,301 | $5,000 | Implemented |
UA0099 # 04 Y:2013 | 04 | 2013 | OPTIMIZE PLANT POWER FACTOR | $19,434 | $14,980 | Not Implemented |
UA0099 # 03 Y:2013 | 03 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $25,020 | $52,360 | Not Implemented |
UA0099 # 02 Y:2013 | 02 | 2013 | DISCONNECT BALLASTS | $3,632 | $242 | Not Implemented |
UA0096 # 08 Y:2013 | 08 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $321 | $1,000 | Not Implemented |
UA0096 # 07 Y:2013 | 07 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $485 | $400 | Not Implemented |
UA0096 # 06 Y:2013 | 06 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $766 | $8 | Not Implemented |
UA0096 # 05 Y:2013 | 05 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $3,456 | $1,320 | Implemented |
UA0096 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $1,997 | $545 | Implemented |
UA0096 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,715 | $39,573 | Implemented |
UA0096 # 02 Y:2013 | 02 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $817 | $996 | Implemented |
UA0096 # 01 Y:2013 | 01 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $13,079 | $0 | Implemented |