Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

48

matching recommendations
Reset
SIC 3085 Plastics Bottles
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0193 # 06 Y:2000 06 2000 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $64,272 $64,142 Not Implemented
NC0193 # 05 Y:2000 05 2000 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $35,491 $500 Not Implemented
NC0193 # 04 Y:2000 04 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,211 $3,850 Not Implemented
NC0193 # 03 Y:2000 03 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,422 $56 Not Implemented
NC0193 # 02 Y:2000 02 2000 DEVELOP A REPAIR/REPLACE POLICY $3,831 $3,617 Implemented
NC0193 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $762 $3,710 Not Implemented
NC0193 # 07 Y:2000 07 2000 $23,000 $1,000 Not Implemented
NC0058 # 05 Y:1995 05 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,618 $2,500 Implemented
NC0058 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $149 $292 Implemented
NC0058 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $16,902 $30,410 Implemented
NC0058 # 03 Y:1995 03 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,940 $10,000 Not Implemented
NC0058 # 04 Y:1995 04 1995 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $19,158 $80,000 Not Implemented
NC0058 # 06 Y:1995 06 1995 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $20,246 $4,000 Not Implemented
NC0058 # 07 Y:1995 07 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,975 $240 Implemented
NC0058 # 08 Y:1995 08 1995 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $13,702 $0 Implemented
NC0058 # 09 Y:1995 09 1995 INSULATE BARE EQUIPMENT $4,862 $1,500 Not Implemented
TN0390 # 01 Y:1990 01 1990 IMPROVE LUBRICATION PRACTICES $44,021 $13,500 Implemented
TN0390 # 02 Y:1990 02 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $39,625 $5,440 Implemented
TN0390 # 03 Y:1990 03 1990 INSTALL TIMERS AND/OR THERMOSTATS $11,893 $1,200 Implemented
TN0390 # 04 Y:1990 04 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $28,121 $12,250 Implemented
TN0390 # 05 Y:1990 05 1990 KEEP LAMPS AND REFLECTORS CLEAN $1,983 $5,850 Implemented
TN0390 # 06 Y:1990 06 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $703 $438 Implemented
TN0390 # 07 Y:1990 07 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $167,999 $976,000 Implemented