Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

77

matching recommendations
Reset
NAICS 332812 Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0826 # 08 Y:2010 08 2010 IMPROVE COMBUSTION CONTROL CAPABILITY $10,244 $2,000 Not Implemented
WV0326 # 01 Y:2005 01 2005 INSULATE BARE EQUIPMENT $6,011 $1,797 Implemented
WV0326 # 12 Y:2005 12 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $295 $180 Implemented
WV0326 # 11 Y:2005 11 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $388 $140 Not Implemented
WV0326 # 10 Y:2005 10 2005 DEVELOP A REPAIR/REPLACE POLICY $459 $54 Implemented
WV0326 # 09 Y:2005 09 2005 USE SYNTHETIC LUBRICANT $577 $17 Implemented
WV0326 # 08 Y:2005 08 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $652 $367 Implemented
WV0326 # 07 Y:2005 07 2005 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $780 $1,076 Implemented
WV0326 # 06 Y:2005 06 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,047 $3,517 Not Implemented
WV0326 # 05 Y:2005 05 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,818 $1,000 Implemented
WV0326 # 04 Y:2005 04 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,621 $2,722 Not Implemented
WV0326 # 03 Y:2005 03 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,386 $1,840 Implemented
WV0326 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,897 $14,339 Implemented
UD0697 # 07 Y:2004 07 2004 USE PHOTOCELL CONTROLS $2,756 $11,325 Not Implemented
UD0697 # 06 Y:2004 06 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,816 $10,786 Not Implemented
UD0697 # 05 Y:2004 05 2004 INSTALL TIMERS AND/OR THERMOSTATS $2,868 $770 Not Implemented
UD0697 # 04 Y:2004 04 2004 REDUCE FLUID FLOW RATES $2,950 $0 Implemented
UD0697 # 03 Y:2004 03 2004 COVER OPEN TANKS $5,579 $3,590 Not Implemented
UD0697 # 02 Y:2004 02 2004 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $11,330 $0 Implemented
UD0697 # 08 Y:2004 08 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,294 $100 Not Implemented
UD0697 # 09 Y:2004 09 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $1,414 $100 Not Implemented
UD0697 # 10 Y:2004 10 2004 REDUCE VENTILATION AIR $804 $0 Not Implemented
UD0697 # 11 Y:2004 11 2004 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $782 $0 Implemented
UD0697 # 12 Y:2004 12 2004 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $244 $0 Implemented
UD0697 # 13 Y:2004 13 2004 INSULATE BARE EQUIPMENT $240 $91 Implemented