Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

96

matching recommendations
Reset
SIC 2752 Commercial Printing, Lithographic
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0584 # 03 Y:1999 03 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $981 $356 Implemented
UM0107 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,746 $3,572 Not Implemented
UM0107 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $250 $250 Not Implemented
UM0107 # 03 Y:1998 03 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $7,179 $250 Not Implemented
UM0107 # 06 Y:1998 06 1998 $14,550 $5,200 Not Implemented
UM0107 # 04 Y:1998 04 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $130 $100 Not Implemented
UM0107 # 05 Y:1998 05 1998 $10,400 $2,250 Not Implemented
UD0526 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,181 $11,751 Implemented
UD0526 # 02 Y:1997 02 1997 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,197 $5,000 Implemented
UD0526 # 01 Y:1997 01 1997 OPTIMIZE PLANT POWER FACTOR $14,725 $15,000 Implemented
UD0524 # 02 Y:1997 02 1997 USE OPTIMUM THICKNESS INSULATION $1,914 $9,400 Implemented
UD0524 # 01 Y:1997 01 1997 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $1,145 $0 Implemented
UD0524 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $9,568 $0 Not Implemented
UD0524 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,898 $16,158 Implemented
UD0524 # 05 Y:1997 05 1997 REPLACE DC EQUIPMENT WITH AC EQUIPMENT $5,400 $22,500 Implemented
UD0410 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,630 $2,630 Not Implemented
UD0410 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $22,462 $22,462 Implemented
UD0410 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,156 $5,156 Implemented
UD0410 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,000 $12,000 Implemented
UD0410 # 02 Y:1993 02 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $0 $0 Not Implemented
UD0410 # 01 Y:1993 01 1993 OPTIMIZE PLANT POWER FACTOR $2,250 $2,250 Not Implemented
UD0410 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,650 $4,650 Not Implemented
UD0315 # 03 Y:1990 03 1990 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $33,180 $70,000 Implemented
UD0313 # 01 Y:1990 01 1990 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $5,744 $20,000 Implemented
UD0313 # 03 Y:1990 03 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $260 $240 Not Implemented