IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

36

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0555 # 06 Y:1998 06 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,882 $17,546 Implemented
UD0555 # 04 Y:1998 04 1998 ELIMINATE/REDUCE AN OPERATION $17,490 $0 Implemented
UD0555 # 02 Y:1998 02 1998 $123,160 $115,000 Not Implemented
UD0555 # 05 Y:1998 05 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $11,454 $0 Implemented
UD0555 # 01 Y:1998 01 1998 $237,283 $1,313,000 Implemented
UD0555 # 03 Y:1998 03 1998 RECOVER WASTE HEAT FROM EQUIPMENT $22,667 $20,000 Not Implemented
UD0554 # 04 Y:1998 04 1998 INSULATE BARE EQUIPMENT $19,707 $21,120 Not Implemented
UD0554 # 07 Y:1998 07 1998 COVER OPEN TANKS $2,023 $1,050 Implemented
UD0554 # 06 Y:1998 06 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,699 $6,419 Not Implemented
UD0554 # 05 Y:1998 05 1998 INSTALL / REPAIR INSULATION ON STEAM LINES $4,026 $1,850 Implemented
UD0554 # 03 Y:1998 03 1998 $28,560 $8,000 Implemented
UD0554 # 02 Y:1998 02 1998 $47,736 $2,000 Not Implemented
UD0554 # 01 Y:1998 01 1998 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $101,400 $60,000 Not Implemented
WV0133 # 13 Y:1998 13 1998 $11,375 $2,520 Implemented
WV0133 # 12 Y:1998 12 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $3,600 $0 Implemented
WV0133 # 11 Y:1998 11 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $6,796 $11,000 Not Implemented
WV0133 # 10 Y:1998 10 1998 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $1,372 $7,000 Implemented
WV0133 # 09 Y:1998 09 1998 USE RADIANT HEATER FOR SPOT HEATING $18,727 $350 Not Implemented
WV0133 # 08 Y:1998 08 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $72,430 $100,440 Implemented
WV0133 # 07 Y:1998 07 1998 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,854 $1,210 Not Implemented
WV0133 # 06 Y:1998 06 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,834 $6,000 Implemented
WV0133 # 05 Y:1998 05 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,194 $2,900 Not Implemented
WV0133 # 03 Y:1998 03 1998 USE SYNTHETIC LUBRICANT $3,504 $405 Implemented
WV0133 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,917 $248 Not Implemented
WV0133 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,705 $2,273 Implemented