Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0506 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $11,388 | $8,000 | Implemented |
UD0506 # 02 Y:1996 | 02 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,091 | $0 | Implemented |
UD0506 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,416 | $31,170 | Implemented |
UD0506 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,316 | $41,520 | Implemented |
WV0096 # 05 Y:1996 | 05 | 1996 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $3,406 | $490 | Implemented |
WV0096 # 04 Y:1996 | 04 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $538 | $1,447 | Not Implemented |
WV0096 # 03 Y:1996 | 03 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $275 | $200 | Implemented |
WV0096 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,892 | $4,029 | Implemented |
WV0096 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,010 | $302 | Implemented |
WV0096 # 06 Y:1996 | 06 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $5,420 | $8,250 | Not Implemented |
WV0095 # 01 Y:1996 | 01 | 1996 | USE POWER DURING OFF-PEAK PERIODS | $24,235 | $0 | Implemented |
WV0095 # 09 Y:1996 | 09 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $11,260 | $9,000 | Implemented |
WV0095 # 08 Y:1996 | 08 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,432 | $2,800 | Not Implemented |
WV0095 # 07 Y:1996 | 07 | 1996 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $8,019 | $2,940 | Not Implemented |
WV0095 # 06 Y:1996 | 06 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $580 | $0 | Implemented |
WV0095 # 05 Y:1996 | 05 | 1996 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,811 | $2,743 | Implemented |
WV0095 # 04 Y:1996 | 04 | 1996 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $534 | $2,105 | Not Implemented |
WV0095 # 03 Y:1996 | 03 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $466 | $700 | Implemented |
WV0095 # 02 Y:1996 | 02 | 1996 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $4,565 | $550 | Implemented |
UD0488 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $4,372 | $4,000 | Implemented |
UD0488 # 02 Y:1996 | 02 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,843 | $3,000 | Implemented |
UD0488 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,037 | $8,010 | Implemented |
UD0488 # 03 Y:1996 | 03 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $997 | $2,500 | Not Implemented |
UD0485 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,249 | $12,150 | Implemented |
UD0485 # 03 Y:1996 | 03 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,528 | $250 | Implemented |