Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

52

matching recommendations
Reset
SIC 3672 Printed Circuit Boards
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0254 # 08 Y:2002 08 2002 INSULATE BARE EQUIPMENT $1,756 $483 Implemented
WV0254 # 01 Y:2002 01 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,829 $420 Not Implemented
WV0254 # 02 Y:2002 02 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,033 $120 Implemented
WV0254 # 03 Y:2002 03 2002 RECOVER WASTE HEAT FROM EQUIPMENT $7,900 $460 Not Implemented
WV0254 # 04 Y:2002 04 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $14,421 $1,200 Not Implemented
WV0254 # 05 Y:2002 05 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,172 $200 Implemented
WV0254 # 06 Y:2002 06 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $755 $600 Implemented
WV0254 # 15 Y:2002 15 2002 $14,000 $6,000 Not Implemented
UD0620 # 07 Y:2001 07 2001 MINIMIZE WATER USAGE $876 $750 Not Implemented
UD0620 # 06 Y:2001 06 2001 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,218 $0 Implemented
UD0620 # 05 Y:2001 05 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,470 $3,648 Implemented
UD0620 # 04 Y:2001 04 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,850 $0 Not Implemented
UD0620 # 03 Y:2001 03 2001 RECOVER AND REUSE SPENT ACID BATHS $2,250 $0 Not Implemented
UD0620 # 02 Y:2001 02 2001 RECOVER WASTE HEAT FROM EQUIPMENT $6,449 $300 Not Implemented
UD0620 # 01 Y:2001 01 2001 RECOVER AND REUSE SPENT ACID BATHS $42,596 $85,000 Not Implemented
UD0620 # 08 Y:2001 08 2001 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $756 $0 Implemented
UD0402 # 06 Y:1993 06 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,782 $15,000 Implemented
UD0402 # 01 Y:1993 01 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $10,502 $0 Implemented
UD0402 # 02 Y:1993 02 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,564 $0 Not Implemented
UD0402 # 03 Y:1993 03 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $1,064 $0 Implemented
UD0402 # 04 Y:1993 04 1993 RECOVER WASTE HEAT FROM EQUIPMENT $4,680 $1,500 Implemented
UD0402 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,502 $25,812 Implemented
UD0402 # 07 Y:1993 07 1993 INSTALL TIMERS AND/OR THERMOSTATS $2,295 $1,350 Implemented
UD0283 # 03 Y:1989 03 1989 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $738 $0 Implemented
UD0283 # 02 Y:1989 02 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,833 $3,000 Implemented