Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
406
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0680 # 09 Y:2003 | 09 | 2003 | OPTIMIZE PLANT POWER FACTOR | $4,028 | $5,000 | Not Implemented |
UD0680 # 03 Y:2003 | 03 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $9,824 | $2,160 | Not Implemented |
UD0680 # 06 Y:2003 | 06 | 2003 | IMPROVE COMBUSTION CONTROL CAPABILITY | $6,819 | $0 | Not Implemented |
UD0680 # 17 Y:2003 | 17 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,200 | $470 | Not Implemented |
UD0680 # 12 Y:2003 | 12 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,465 | $900 | Implemented |
UD0680 # 15 Y:2003 | 15 | 2003 | DISCONNECT BALLASTS | $1,248 | $0 | Not Implemented |
UD0680 # 11 Y:2003 | 11 | 2003 | COVER OPEN TANKS | $2,708 | $1,375 | Implemented |
UD0680 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,243 | $14,256 | Implemented |
UD0680 # 16 Y:2003 | 16 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,235 | $90 | Not Implemented |
UD0679 # 08 Y:2003 | 08 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,200 | $1,750 | n/a |
UD0679 # 03 Y:2003 | 03 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $12,046 | $270 | n/a |
UD0679 # 01 Y:2003 | 01 | 2003 | REDUCE VENTILATION AIR | $241,706 | $-3,800,000 | n/a |
UD0679 # 05 Y:2003 | 05 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,465 | $200 | n/a |
UD0679 # 11 Y:2003 | 11 | 2003 | INSTALL OCCUPANCY SENSORS | $232 | $110 | n/a |
UD0679 # 10 Y:2003 | 10 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,739 | $3,618 | n/a |
UD0679 # 09 Y:2003 | 09 | 2003 | DISCONNECT BALLASTS | $3,797 | $132 | n/a |
UD0679 # 06 Y:2003 | 06 | 2003 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $7,398 | $0 | n/a |
UD0679 # 07 Y:2003 | 07 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,070 | $7,100 | n/a |
UD0679 # 02 Y:2003 | 02 | 2003 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $52,385 | $1,125 | n/a |
UD0679 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,330 | $1,100 | n/a |
UD0678 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,840 | $0 | Implemented |
UD0678 # 07 Y:2003 | 07 | 2003 | USE OPTIMUM TEMPERATURE | $5,406 | $500 | Not Implemented |
UD0678 # 11 Y:2003 | 11 | 2003 | DISCONNECT BALLASTS | $1,865 | $90 | Implemented |
UD0678 # 10 Y:2003 | 10 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,251 | $2,000 | Implemented |
UD0678 # 06 Y:2003 | 06 | 2003 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $6,015 | $3,150 | Not Implemented |