Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

101

matching recommendations
Reset
NAICS 325 Chemical Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0737 # 02 Y:2006 02 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $7,798 $11,625 Not Implemented
OK0737 # 03 Y:2006 03 2006 REPAIR OR REPLACE STEAM TRAPS $92,687 $1,025 Not Implemented
OK0737 # 04 Y:2006 04 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $30,440 $19,260 Not Implemented
OK0737 # 05 Y:2006 05 2006 MODERATE COOLING TOWER OUTLET TEMPERATURE $28,248 $15,000 Not Implemented
OK0727 # 01 Y:2006 01 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,431 $2,462 Implemented
OK0727 # 02 Y:2006 02 2006 INSTALL TIMERS AND/OR THERMOSTATS $1,646 $75 Implemented
OK0727 # 03 Y:2006 03 2006 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $12,463 $40,452 Not Implemented
OK0727 # 04 Y:2006 04 2006 USE GRAVITY FEEDS WHEREVER POSSIBLE $10,056 $1,636 Not Implemented
OK0727 # 05 Y:2006 05 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,960 $8,407 Not Implemented
OK0727 # 06 Y:2006 06 2006 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $117,767 $838,833 Not Implemented
OK0727 # 07 Y:2006 07 2006 INSULATE BARE EQUIPMENT $14,689 $7,635 Implemented
OK0727 # 08 Y:2006 08 2006 INSTALL OCCUPANCY SENSORS $676 $535 Not Implemented
OK0710 # 01 Y:2005 01 2005 AVOID EMERGENCY REWIND OF MOTORS $18,566 $18,454 Not Implemented
OK0710 # 02 Y:2005 02 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,475 $3,550 Implemented
OK0710 # 03 Y:2005 03 2005 INSTALL SET-BACK TIMERS $1,403 $430 Not Implemented
OK0710 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,823 $1,607 Not Implemented
OK0710 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,439 $4,746 Implemented
OK0710 # 06 Y:2005 06 2005 INSTALL OCCUPANCY SENSORS $467 $356 Not Implemented
OK0710 # 07 Y:2005 07 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $729 $30 Not Implemented
OK0710 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $298 $895 Not Implemented
OK0709 # 01 Y:2005 01 2005 USE POWER DURING OFF-PEAK PERIODS $2,560 $0 Not Implemented
OK0709 # 02 Y:2005 02 2005 INSULATE BARE EQUIPMENT $3,684 $1,030 Implemented
OK0709 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,659 $11,363 Not Implemented
OK0709 # 04 Y:2005 04 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $11,493 $21,700 Not Implemented
OK0709 # 05 Y:2005 05 2005 $1,000 $0 Not Implemented