Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
118
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0615 # 10 Y:2001 | 10 | 2001 | REPLACE BOILER | $7,761 | $22,000 | Not Implemented |
OK0615 # 06 Y:2001 | 06 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,998 | $6,000 | Not Implemented |
OK0615 # 07 Y:2001 | 07 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $536 | $163 | Implemented |
OK0615 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,798 | $913 | Not Implemented |
OK0615 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,895 | $5,476 | Implemented |
OK0615 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $1,844 | $585 | Implemented |
OK0615 # 04 Y:2001 | 04 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,788 | $250 | Implemented |
OK0615 # 05 Y:2001 | 05 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,147 | $238 | Not Implemented |
OK0615 # 09 Y:2001 | 09 | 2001 | CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS | $13,745 | $240 | Implemented |
OK0615 # 08 Y:2001 | 08 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $20,688 | $8,572 | Not Implemented |
OK0630 # 04 Y:2001 | 04 | 2001 | INSTALL SET-BACK TIMERS | $11,800 | $3,370 | Implemented |
OK0630 # 07 Y:2001 | 07 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,542 | $1,800 | Not Implemented |
OK0630 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,953 | $300 | Implemented |
OK0630 # 05 Y:2001 | 05 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $28,600 | $5,000 | Not Implemented |
OK0630 # 02 Y:2001 | 02 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,400 | $0 | Not Implemented |
OK0630 # 06 Y:2001 | 06 | 2001 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $115,000 | $180,000 | Not Implemented |
OK0630 # 03 Y:2001 | 03 | 2001 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,994 | $3,700 | Implemented |
OK0632 # 08 Y:2001 | 08 | 2001 | MOVE PRODUCT USING MECHANICAL MEANS | $19,500 | $2,500 | Implemented |
OK0632 # 09 Y:2001 | 09 | 2001 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $19,500 | $2,305 | Not Implemented |
OK0632 # 06 Y:2001 | 06 | 2001 | MOVE PRODUCT USING MECHANICAL MEANS | $11,700 | $2,112 | Implemented |
OK0632 # 04 Y:2001 | 04 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $936 | $0 | Implemented |
OK0632 # 05 Y:2001 | 05 | 2001 | INSTALL SET-BACK TIMERS | $3,073 | $940 | Implemented |
OK0632 # 03 Y:2001 | 03 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $451 | $2,456 | Implemented |
OK0632 # 02 Y:2001 | 02 | 2001 | INSTALL SET-BACK TIMERS | $2,867 | $250 | Not Implemented |
OK0632 # 07 Y:2001 | 07 | 2001 | MODIFY WORKLOAD | $1,800 | $0 | Implemented |