Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
50
matching recommendationsSIC | 24 | Lumber And Wood Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0160 # 07 Y:1992 | 07 | 1992 | OPTIMIZE PLANT POWER FACTOR | $13,194 | $10,500 | Implemented |
OR0160 # 06 Y:1992 | 06 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $306 | $1,270 | Implemented |
OR0160 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,017 | $1,244 | Implemented |
OR0160 # 02 Y:1992 | 02 | 1992 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,022,395 | $250,000 | Implemented |
OR0161 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $4,535 | $0 | Implemented |
OR0161 # 02 Y:1992 | 02 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $289 | $90 | Implemented |
OR0161 # 05 Y:1992 | 05 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $911 | $0 | Implemented |
OR0161 # 01 Y:1992 | 01 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $384 | $30 | Implemented |
OR0159 # 03 Y:1992 | 03 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,062 | $4,140 | Implemented |
OR0159 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,001 | $4,750 | Implemented |
OR0159 # 01 Y:1992 | 01 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,183 | $670 | Implemented |
OR0159 # 04 Y:1992 | 04 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,364 | $928 | Implemented |
OR0159 # 07 Y:1992 | 07 | 1992 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $10,380 | $9,000 | Implemented |
OR0155 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,826 | $0 | Implemented |
OR0155 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,086 | $2,240 | Implemented |
OR0155 # 03 Y:1992 | 03 | 1992 | INSTALL SET-BACK TIMERS | $4,699 | $0 | Implemented |
OR0155 # 02 Y:1992 | 02 | 1992 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,144 | $0 | Implemented |
OR0155 # 01 Y:1992 | 01 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $62,000 | $1,000 | Implemented |
OR0154 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $206 | $575 | Implemented |
OR0154 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,765 | $3,500 | Implemented |
OR0154 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,181 | $0 | Implemented |
OR0154 # 01 Y:1992 | 01 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $457 | $0 | Implemented |
OR0153 # 03 Y:1992 | 03 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $15,051 | $2,000 | Implemented |
OR0153 # 02 Y:1992 | 02 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $91,759 | $2,500 | Implemented |
OR0153 # 01 Y:1992 | 01 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,759 | $0 | Implemented |