Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0251 # 04 Y:1995 | 04 | 1995 | INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER | $145,120 | $1,495,000 | Not Implemented |
OR0251 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,652 | $17,025 | Not Implemented |
OR0251 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,007 | $9,588 | Implemented |
OR0251 # 01 Y:1995 | 01 | 1995 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $69,966 | $115,000 | Implemented |
OR0246 # 06 Y:1995 | 06 | 1995 | OPTIMIZE PLANT POWER FACTOR | $5,000 | $14,000 | Not Implemented |
OR0246 # 05 Y:1995 | 05 | 1995 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $2,530 | $6,500 | Implemented |
OR0246 # 04 Y:1995 | 04 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $122,760 | $205,000 | Implemented |
OR0246 # 03 Y:1995 | 03 | 1995 | MINIMIZE WATER USAGE | $3,070 | $0 | Implemented |
OR0246 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,521 | $6,281 | Implemented |
OR0246 # 01 Y:1995 | 01 | 1995 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $12,000 | $19,000 | Not Implemented |
OR0244 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $700 | $1,195 | Implemented |
OR0244 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $14,400 | $5,385 | Not Implemented |
OR0244 # 02 Y:1995 | 02 | 1995 | UPGRADE CONTROLS ON COMPRESSORS | $1,725 | $200 | Implemented |
OR0244 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,764 | $14,938 | Implemented |
OR0242 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,846 | $20,911 | Implemented |
OR0242 # 09 Y:1995 | 09 | 1995 | USE SAND FOR OTHER PURPOSES (EG CONSTRUCTION FILL, COVER FOR MUNICIPAL LANDFILLS) | $157,000 | $1,200 | Implemented |
OR0242 # 08 Y:1995 | 08 | 1995 | USE SAND FOR OTHER PURPOSES (EG CONSTRUCTION FILL, COVER FOR MUNICIPAL LANDFILLS) | $140,600 | $168,000 | Not Implemented |
OR0242 # 07 Y:1995 | 07 | 1995 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $22,000 | $1,000 | Not Implemented |
OR0242 # 06 Y:1995 | 06 | 1995 | IMPROVE COMBUSTION CONTROL CAPABILITY | $89,600 | $225,000 | Not Implemented |
OR0242 # 05 Y:1995 | 05 | 1995 | OPTIMIZE PLANT POWER FACTOR | $1,971 | $6,800 | Not Implemented |
OR0242 # 04 Y:1995 | 04 | 1995 | $2,587 | $3,400 | Implemented | |
OR0242 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,005 | $2,912 | Implemented |
OR0242 # 02 Y:1995 | 02 | 1995 | UPGRADE CONTROLS ON COMPRESSORS | $5,468 | $200 | Implemented |