Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
41
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0223 # 09 Y:2001 | 09 | 2001 | $216,000 | $400,000 | Not Implemented | |
WV0223 # 08 Y:2001 | 08 | 2001 | $92,576 | $12,000 | Not Implemented | |
WV0223 # 07 Y:2001 | 07 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $13,680 | $220 | Implemented |
WV0223 # 06 Y:2001 | 06 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,567 | $44 | Implemented |
WV0223 # 05 Y:2001 | 05 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $7,635 | $1,344 | Implemented |
WV0223 # 04 Y:2001 | 04 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,630 | $386 | Not Implemented |
WV0223 # 03 Y:2001 | 03 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,270 | $124 | Implemented |
WV0223 # 02 Y:2001 | 02 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,692 | $300 | Implemented |
WV0223 # 01 Y:2001 | 01 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,194 | $1,000 | Not Implemented |
WV0222 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $935 | $100 | Implemented |
WV0222 # 13 Y:2001 | 13 | 2001 | $15,000 | $332 | Implemented | |
WV0222 # 12 Y:2001 | 12 | 2001 | $45,760 | $5,000 | Implemented | |
WV0222 # 11 Y:2001 | 11 | 2001 | RECYCLE FLUORESCENT LAMPS | $3,390 | $352 | Implemented |
WV0222 # 10 Y:2001 | 10 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,376 | $1,528 | Not Implemented |
WV0222 # 09 Y:2001 | 09 | 2001 | BURN WASTE OIL FOR HEAT | $2,857 | $3,172 | Not Implemented |
WV0222 # 08 Y:2001 | 08 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,491 | $44 | Implemented |
WV0222 # 07 Y:2001 | 07 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,470 | $208 | Not Implemented |
WV0222 # 06 Y:2001 | 06 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $13,220 | $1,792 | Implemented |
WV0222 # 05 Y:2001 | 05 | 2001 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,036 | $1,025 | Not Implemented |
WV0222 # 04 Y:2001 | 04 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,685 | $880 | Implemented |
WV0222 # 03 Y:2001 | 03 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,296 | $1,000 | Implemented |
WV0222 # 01 Y:2001 | 01 | 2001 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $16,581 | $2,904 | Not Implemented |
LE0110 # 01 Y:2001 | 01 | 2001 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $19,815 | $300 | Implemented |
LE0110 # 02 Y:2001 | 02 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,255 | $850 | Not Implemented |
LE0110 # 03 Y:2001 | 03 | 2001 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,628 | $500 | Implemented |