IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

129

matching recommendations
Reset
SIC 28 Chemicals And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0609 # 01 Y:1997 01 1997 COMBINE UTILITY METERS $78,900 $0 Not Implemented
GT0609 # 02 Y:1997 02 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $22,270 $19,740 Not Implemented
GT0609 # 03 Y:1997 03 1997 REDUCE EXCESSIVE BOILER BLOWDOWN $3,060 $0 Not Implemented
GT0609 # 04 Y:1997 04 1997 $181,260 $181,000 Not Implemented
GT0609 # 05 Y:1997 05 1997 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $9,314 $12,000 Not Implemented
GT0609 # 06 Y:1997 06 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,245 $4,110 Implemented
GT0609 # 07 Y:1997 07 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,860 $11,000 Implemented
TN0581 # 01 Y:1996 01 1996 RECOVER AND REUSE WASTE MATERIAL $25,995 $6,250 Not Implemented
TN0581 # 02 Y:1996 02 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $20,270 $23,940 Not Implemented
TN0581 # 03 Y:1996 03 1996 INSTALL TIMERS AND/OR THERMOSTATS $2,790 $1,000 Not Implemented
TN0581 # 04 Y:1996 04 1996 USE MINIMUM STEAM OPERATING PRESSURE $2,360 $2,600 Not Implemented
TN0581 # 05 Y:1996 05 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,600 $0 Not Implemented
TN0581 # 06 Y:1996 06 1996 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $455 $0 Implemented
TN0562 # 01 Y:1995 01 1995 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,813 $4,640 Not Implemented
TN0562 # 02 Y:1995 02 1995 REPAIR AND ELIMINATE STEAM LEAKS $4,419 $450 Implemented
TN0562 # 03 Y:1995 03 1995 CLOSE OFF UNNEEDED STEAM LINES $1,156 $0 Not Implemented
TN0562 # 04 Y:1995 04 1995 USE MINIMUM STEAM OPERATING PRESSURE $1,139 $0 Not Implemented
TN0562 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,209 $2,000 Not Implemented
TN0562 # 06 Y:1995 06 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $1,231 $0 Implemented
TN0562 # 07 Y:1995 07 1995 INSULATE BARE EQUIPMENT $152 $60 Implemented
TN0562 # 08 Y:1995 08 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $963 $530 Implemented
TN0562 # 09 Y:1995 09 1995 RECOVER AND REUSE WASTE MATERIAL $26,496 $26,600 Implemented
TN0562 # 10 Y:1995 10 1995 RECOVER AND REUSE WASTE MATERIAL $13,248 $26,200 Not Implemented
TN0562 # 11 Y:1995 11 1995 IMPROVE HANDLING PRACTICES $45,080 $25,000 Implemented
TN0562 # 12 Y:1995 12 1995 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $50,142 $23,600 Not Implemented