Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

177

matching recommendations
Reset
NAICS 325 Chemical Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0033 # 02 Y:2009 02 2009 REPAIR OR REPLACE STEAM TRAPS $78,500 $40,000 Implemented
TT0033 # 03 Y:2009 03 2009 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $45,100 $15,000 Not Implemented
TT0033 # 04 Y:2009 04 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $18,000 $36,000 Not Implemented
TT0033 # 05 Y:2009 05 2009 INCREASE AMOUNT OF CONDENSATE RETURNED $7,848 $8,000 Not Implemented
TT0033 # 06 Y:2009 06 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,616 $2,500 Implemented
TT0033 # 07 Y:2009 07 2009 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $8,200 $0 Implemented
TT0033 # 08 Y:2009 08 2009 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $24,600 $27,800 Implemented
MS0335 # 01 Y:2008 01 2008 REPAIR AND ELIMINATE STEAM LEAKS $38,137 $280 Not Implemented
MS0335 # 02 Y:2008 02 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $24,959 $7,500 Not Implemented
MS0335 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $43,147 $30,570 Implemented
MS0335 # 04 Y:2008 04 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $17,965 $34,830 Not Implemented
MS0335 # 05 Y:2008 05 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,037 $389 Implemented
MS0335 # 06 Y:2008 06 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,045 $8,725 Implemented
MS0335 # 07 Y:2008 07 2008 INSTALL OCCUPANCY SENSORS $1,338 $13,840 Not Implemented
MS0335 # 08 Y:2008 08 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,515 $476 Not Implemented
MS0273 # 01 Y:2005 01 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $16,069 $12,540 Not Implemented
MS0273 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,056 $26,912 Not Implemented
MS0273 # 03 Y:2005 03 2005 REPAIR AND ELIMINATE STEAM LEAKS $7,498 $89 Implemented
MS0273 # 04 Y:2005 04 2005 RECOVER WASTE HEAT FROM EQUIPMENT $5,737 $685 Not Implemented
MS0273 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,326 $19,601 Not Implemented
MS0273 # 06 Y:2005 06 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,219 $1,480 Not Implemented
MS0273 # 07 Y:2005 07 2005 PAY UTILITY BILLS ON TIME $3,704 $0 Implemented
MS0273 # 08 Y:2005 08 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,474 $203 Not Implemented
MS0273 # 09 Y:2005 09 2005 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $2,353 $231 Not Implemented
MS0273 # 10 Y:2005 10 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,338 $1,215 Not Implemented