Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
480
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KG0073 # 11 Y:1996 | 11 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $34,825 | $500 | Implemented |
KG0070 # 04 Y:1996 | 04 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $2,582 | $600 | Implemented |
KG0070 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,084 | $464 | Implemented |
KG0070 # 06 Y:1996 | 06 | 1996 | REDUCE SCRAP PRODUCTION | $24,864 | $5,000 | Implemented |
KG0070 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,060 | $4,750 | Implemented |
KG0070 # 05 Y:1996 | 05 | 1996 | REDUCE SCRAP PRODUCTION | $3,326 | $500 | Implemented |
KG0070 # 01 Y:1996 | 01 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,417 | $0 | Not Implemented |
KG0072 # 03 Y:1996 | 03 | 1996 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $3,396 | $1,500 | Implemented |
KG0072 # 07 Y:1996 | 07 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $955 | $0 | Not Implemented |
KG0072 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,255 | $1,900 | Not Implemented |
KG0072 # 02 Y:1996 | 02 | 1996 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,206 | $0 | Implemented |
KG0072 # 06 Y:1996 | 06 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $966 | $150 | Not Implemented |
KG0072 # 08 Y:1996 | 08 | 1996 | REDUCE SCRAP PRODUCTION | $21,888 | $2,000 | Not Implemented |
KG0072 # 04 Y:1996 | 04 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,330 | $25 | Implemented |
KG0072 # 01 Y:1996 | 01 | 1996 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,148 | $0 | Not Implemented |
AM0285 # 04 Y:1996 | 04 | 1996 | SHIP HYDRAULIC OIL TO SECONDARY FUEL PROGRAM | $465 | $0 | Not Implemented |
AM0285 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $30,300 | $47,880 | Not Implemented |
AM0285 # 05 Y:1996 | 05 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $340 | $0 | Not Implemented |
AM0285 # 03 Y:1996 | 03 | 1996 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,830 | $5,660 | Implemented |
AM0285 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $49,000 | $70,000 | Implemented |
AM0284 # 07 Y:1996 | 07 | 1996 | INSULATE BARE EQUIPMENT | $260 | $27 | Not Implemented |
AM0284 # 01 Y:1996 | 01 | 1996 | UPGRADE OBSOLETE EQUIPMENT | $899,930 | $2,500,000 | Implemented |
AM0284 # 06 Y:1996 | 06 | 1996 | USE SYNTHETIC LUBRICANT | $300 | $0 | Not Implemented |
AM0284 # 04 Y:1996 | 04 | 1996 | CONVERT TO AQUEOUS CLEANING SYSTEM | $6,652 | $6,168 | Implemented |
AM0284 # 02 Y:1996 | 02 | 1996 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $13,620 | $15,360 | Implemented |