Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, Kingsville |
---|---|
Assessment Year | 1996 |
Principal Product | Concrete pipe and Pre-cast |
NAICS | n/a |
SIC | 3273 - Ready-mixed Concrete |
Sales | $50,000,000-$100,000,000 |
# of Employees | 40 |
Plant Area (Sq.Ft.) | 1,020,085 |
Annual Production | 66,000 Tons |
Production Hrs. Annual | 3,125 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $161,544 | 1,572,098 | kWh | $0.10 |
Electricity Demand | $54,944 | 8,655 | kW-months/year | $6.35 |
Electricity Fees | $6,869 | - | $ | - |
Natural Gas | $35,225 | 6,767 | MMBtu | $5.21 |
TOTAL ENERGY COSTS | $286,772 | |||
RECOMMENDED SAVINGS* | $36,333 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,916 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $2,417 Cost: - |
- | - | - | - | $2,417 | - | - | - |
- - kWh |
- - kW-months/year |
$2,417 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,060 Cost: $4,750 |
$1,629 | 26,084 | $431 | 67 | - | - | - | - |
$1,629 26,084 kWh |
$431 67 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,084 Cost: $464 |
$726 | 11,723 | $358 | 56 | - | - | - | - |
$726 11,723 kWh |
$358 56 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $2,582 Cost: $600 |
$2,582 | 41,325 | - | - | - | - | - | - |
$2,582 41,325 kWh |
- - kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $3,326 Cost: $500 |
- | - | - | - | - | - | $3,326 | 1,300 |
- - kWh |
- - kW-months/year |
- - $ |
$3,326 1,300 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $24,864 Cost: $5,000 |
- | - | - | - | - | - | $24,864 | 432,000 |
- - kWh |
- - kW-months/year |
- - $ |
$24,864 432,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $36,333 Cost: $11,314 |
$4,937 | 79,132 | $789 | 123 | $2,417 | - | $28,190 | 433,300 | $4,937 79,132 kWh |
$789 123 kW-months/year |
$2,417 - $ |
$28,190 433,300 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,916 Cost: $11,314 |
$4,937 | 79,132 | $789 | 123 | - | - | $28,190 | 433,300 | $4,937 79,132 kWh |
$789 123 kW-months/year |
- - $ |
$28,190 433,300 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) |