Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

156

matching recommendations
Reset
SIC 308 Miscellaneous Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0139 # 04 Y:1998 04 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $2,429 $0 Not Implemented
WV0139 # 05 Y:1998 05 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $364 $0 Not Implemented
WV0139 # 06 Y:1998 06 1998 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $66,775 $0 Not Implemented
WV0139 # 07 Y:1998 07 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $398 $448 Not Implemented
WV0139 # 08 Y:1998 08 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $5,400 $100 Implemented
WV0139 # 09 Y:1998 09 1998 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $102 $0 Not Implemented
WV0139 # 10 Y:1998 10 1998 $37,500 $50,000 Implemented
OD0083 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,624 $1,487 n/a
OD0083 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,747 $5,202 n/a
OD0083 # 03 Y:1997 03 1997 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,031 $2,091 n/a
OD0083 # 04 Y:1997 04 1997 RECOVER WASTE HEAT FROM EQUIPMENT $12,028 $5,691 n/a
OD0083 # 05 Y:1997 05 1997 $500,032 $30,482 n/a
OD0013 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,766 $15,710 Not Implemented
OD0013 # 02 Y:1994 02 1994 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,441 $3,000 Implemented
OD0013 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,776 $8,261 Implemented
OD0013 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,197 $3,440 Implemented
OD0013 # 05 Y:1994 05 1994 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $4,076 $140 Implemented
OD0013 # 06 Y:1994 06 1994 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,814 $860 Not Implemented
WV0044 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $68 $687 Implemented
WV0044 # 02 Y:1994 02 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $6,479 $4,000 Not Implemented
WV0044 # 03 Y:1994 03 1994 RECOVER WASTE HEAT FROM EQUIPMENT $13,270 $548 Not Implemented
WV0044 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,195 $1,032 Implemented
WV0044 # 05 Y:1994 05 1994 USE SYNTHETIC LUBRICANT $3,038 $0 Implemented
TN0371 # 01 Y:1989 01 1989 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $24,816 $13,460 Implemented
TN0371 # 02 Y:1989 02 1989 REPAIR AND ELIMINATE STEAM LEAKS $5,334 $600 Implemented