Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

57

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0008 # 02 Y:1993 02 1993 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $3,254 $3,500 Not Implemented
NC0008 # 03 Y:1993 03 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,091 $13,201 Implemented
NC0008 # 04 Y:1993 04 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,736 $13,007 Implemented
NC0008 # 05 Y:1993 05 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,196 $180 Implemented
NC0008 # 06 Y:1993 06 1993 RECOVER WASTE HEAT FROM EQUIPMENT $1,395 $2,500 Not Implemented
NC0008 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,260 $12,244 Implemented
NC0008 # 08 Y:1993 08 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,691 $150 Implemented
NC0008 # 09 Y:1993 09 1993 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $347 $330 Not Implemented
NC0008 # 01 Y:1993 01 1993 RECOVER WASTE HEAT FROM EQUIPMENT $6,237 $750 Not Implemented
TN0494 # 05 Y:1993 05 1993 INSTALL TIMERS AND/OR THERMOSTATS $338 $840 Implemented
TN0494 # 03 Y:1993 03 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $957 $1,710 Implemented
TN0494 # 04 Y:1993 04 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $643 $406 Implemented
TN0494 # 01 Y:1993 01 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $7,383 $26,368 Implemented
TN0494 # 02 Y:1993 02 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,037 $0 Implemented
TN0494 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $463 $1,686 Implemented
TN0494 # 07 Y:1993 07 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $314 $0 Implemented
TN0495 # 03 Y:1993 03 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $6,425 $17,573 Not Implemented
TN0495 # 02 Y:1993 02 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,339 $480 Implemented
TN0495 # 08 Y:1993 08 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $460 $410 Not Implemented
TN0495 # 01 Y:1993 01 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,894 $1,500 Implemented
TN0495 # 06 Y:1993 06 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $876 $775 Implemented
TN0495 # 05 Y:1993 05 1993 USE MINIMUM STEAM OPERATING PRESSURE $1,238 $0 Not Implemented
TN0495 # 10 Y:1993 10 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $230 $490 Not Implemented
TN0495 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $776 $841 Implemented
TN0495 # 04 Y:1993 04 1993 REPAIR AND ELIMINATE STEAM LEAKS $1,551 $285 Implemented