Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
48
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0422 # 03 Y:2002 | 03 | 2002 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $6,975 | $5,500 | Implemented |
OR0422 # 02 Y:2002 | 02 | 2002 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $4,106 | $2,000 | Implemented |
OR0422 # 01 Y:2002 | 01 | 2002 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,067 | $0 | Implemented |
OR0422 # 04 Y:2002 | 04 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,944 | $2,953 | Implemented |
OR0422 # 05 Y:2002 | 05 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $595 | $0 | Implemented |
OR0418 # 04 Y:2002 | 04 | 2002 | OPTIMIZE PLANT POWER FACTOR | $929 | $1,500 | Implemented |
OR0418 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,409 | $1,400 | Implemented |
OR0418 # 03 Y:2002 | 03 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,090 | $1,800 | Implemented |
OR0418 # 05 Y:2002 | 05 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,707 | $9,446 | Implemented |
OR0418 # 02 Y:2002 | 02 | 2002 | UPGRADE CONTROLS ON COMPRESSORS | $6,865 | $7,600 | Implemented |
OR0421 # 05 Y:2002 | 05 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,148 | $6,309 | Implemented |
OR0421 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,964 | $5,062 | Implemented |
OR0421 # 01 Y:2002 | 01 | 2002 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $31,000 | $12,000 | Implemented |
OR0421 # 02 Y:2002 | 02 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $27,311 | $32,500 | Implemented |
OR0421 # 03 Y:2002 | 03 | 2002 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,751 | $9,925 | Not Implemented |
OR0417 # 04 Y:2002 | 04 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,086 | $19,050 | n/a |
OR0416 # 07 Y:2002 | 07 | 2002 | OPTIMIZE PLANT POWER FACTOR | $15,524 | $38,000 | Not Implemented |
OR0417 # 01 Y:2002 | 01 | 2002 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $26,500 | $0 | Not Implemented |
OR0417 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,232 | $0 | Implemented |
OR0417 # 03 Y:2002 | 03 | 2002 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $6,232 | $900 | Implemented |
OR0416 # 06 Y:2002 | 06 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $11,200 | $0 | Not Implemented |
OR0416 # 05 Y:2002 | 05 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $32,840 | $32,942 | Not Implemented |
OR0420 # 05 Y:2002 | 05 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,020 | $1,200 | Implemented |
OR0420 # 04 Y:2002 | 04 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,195 | $5,000 | Implemented |
OR0420 # 01 Y:2002 | 01 | 2002 | CLEAR AND RENT EXISTING SPACE | $39,861 | $1,920 | Not Implemented |