Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
102
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0011 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $357 | $0 | Not Implemented |
WM0011 # 07 Y:2012 | 07 | 2012 | USE A RAG RECYCLE SERVICE | $2,496 | $0 | Not Implemented |
WM0011 # 01 Y:2012 | 01 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $14,000 | $0 | Implemented |
WM0011 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $406 | $600 | Not Implemented |
WM0011 # 04 Y:2012 | 04 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $899 | $1,480 | Not Implemented |
WM0011 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,063 | $440 | Implemented |
WM0011 # 08 Y:2012 | 08 | 2012 | COMBINE UTILITY METERS | $1,110 | $5,000 | Not Implemented |
WM0011 # 03 Y:2012 | 03 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $293 | $265 | Implemented |
WM0011 # 09 Y:2012 | 09 | 2012 | IMPROVE SPACE COMFORT CONDITIONING | $2,993 | $3,000 | Implemented |
WM0016 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,622 | $488 | Not Implemented |
WM0016 # 05 Y:2012 | 05 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,769 | $13,000 | Not Implemented |
WM0016 # 06 Y:2012 | 06 | 2012 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,004 | $0 | Implemented |
WM0016 # 07 Y:2012 | 07 | 2012 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $962 | $5,000 | Not Implemented |
WM0016 # 03 Y:2012 | 03 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,517 | $0 | Implemented |
WM0016 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $957 | $270 | Not Implemented |
WM0016 # 02 Y:2012 | 02 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $652 | $850 | Not Implemented |
WM0012 # 07 Y:2012 | 07 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $62 | $128 | Implemented |
WM0012 # 04 Y:2012 | 04 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,999 | $5,230 | Implemented |
WM0012 # 06 Y:2012 | 06 | 2012 | AIR CONDITION ONLY SPACE NECESSARY | $597 | $975 | Not Implemented |
WM0012 # 02 Y:2012 | 02 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,345 | $375 | Not Implemented |
WM0012 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $771 | $100 | Not Implemented |
WM0012 # 01 Y:2012 | 01 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,304 | $1,675 | Not Implemented |
WM0012 # 05 Y:2012 | 05 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,779 | $4,500 | Not Implemented |
WM0006 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,926 | $0 | Not Implemented |
WM0006 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,581 | $488 | Implemented |