Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,091
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0015 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,595 | $0 | Implemented |
IA0015 # 06 Y:1991 | 06 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,851 | $100 | Implemented |
IA0015 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $846 | $1,980 | Implemented |
IA0015 # 04 Y:1991 | 04 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,364 | $8,000 | Implemented |
IA0015 # 03 Y:1991 | 03 | 1991 | INSTALL SET-BACK TIMERS | $440 | $200 | Implemented |
IA0015 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,300 | $4,278 | Implemented |
IA0015 # 05 Y:1991 | 05 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,896 | $5,370 | Implemented |
KU0360 # 07 Y:1991 | 07 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $377 | $310 | Not Implemented |
KU0360 # 02 Y:1991 | 02 | 1991 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,473 | $22,500 | Not Implemented |
KU0360 # 03 Y:1991 | 03 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,987 | $150 | Not Implemented |
KU0360 # 06 Y:1991 | 06 | 1991 | INSTALL SET-BACK TIMERS | $770 | $1,900 | Not Implemented |
KU0360 # 05 Y:1991 | 05 | 1991 | ISOLATE HOT OR COLD EQUIPMENT | $1,192 | $300 | Not Implemented |
KU0360 # 04 Y:1991 | 04 | 1991 | INSTALL AUTOMATIC STACK DAMPER | $1,794 | $2,525 | Not Implemented |
KU0360 # 01 Y:1991 | 01 | 1991 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $11,710 | $6,000 | Not Implemented |
AM0135 # 03 Y:1991 | 03 | 1991 | INCREASE AMOUNT OF CONDENSATE RETURNED | $870 | $715 | Implemented |
AS0043 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $502 | $176 | Implemented |
AS0043 # 07 Y:1991 | 07 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $124 | $100 | Implemented |
AS0043 # 05 Y:1991 | 05 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $236 | $212 | Implemented |
WI0135 # 07 Y:1991 | 07 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $321 | $400 | Implemented |
AS0043 # 04 Y:1991 | 04 | 1991 | INSTALL SET-BACK TIMERS | $818 | $1,575 | Implemented |
AM0135 # 02 Y:1991 | 02 | 1991 | INSULATE BARE EQUIPMENT | $2,190 | $100 | Implemented |
AS0043 # 08 Y:1991 | 08 | 1991 | IMPROVE LUBRICATION PRACTICES | $124 | $0 | Implemented |
AM0134 # 05 Y:1991 | 05 | 1991 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $14,690 | $0 | Not Implemented |
AM0135 # 01 Y:1991 | 01 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,330 | $6,532 | Implemented |
AM0135 # 04 Y:1991 | 04 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $840 | $1,009 | Implemented |